Determination of benperidol and its reduced metabolite in human plasma by high-performance liquid chromatography and electrochemical detection
Abstract
An isocratic high-performance liquid chromatographic method with electrochemical detection for the quantification of benperidol and its suggested reduced metabolite TVX Q 5402 in human plasma is described. The method included a two-step solid-phase extraction on reversed-phase and cation-exchange material, followed by separation on a cyanopropyl silica gel column (5 microns; 250 mm x 4.6 mm I.D.). The eluent was 0.15 M acetate buffer (pH 4.7) containing 25% acetonitrile (w/w). Spiperone served as internal standard. The inclusion of the cation-exchange step provided sample purity higher than those achieved with other methods. After extraction of 1 ml of plasma, concentrations as low as 0.5 ng/ml were detectable for both benperidol and the metabolite. In plasma samples collected from a schizophrenic patient treated with a single oral dose of 6 mg of benperidol, plasma levels of benperidol and of the metabolite could be measured from 20 min to at least 12 h after administration.
Similar articles
-
Determination of benperidol in human plasma by high-performance liquid chromatography.J Chromatogr. 1984 Nov 9;311(1):109-16. doi: 10.1016/s0378-4347(00)84696-4. J Chromatogr. 1984. PMID: 6520151
-
Electrochemical detection of benperidol in serum for drug monitoring in humans.Ther Drug Monit. 1987 Sep;9(3):343-6. doi: 10.1097/00007691-198709000-00015. Ther Drug Monit. 1987. PMID: 3672579
-
High-performance liquid chromatographic assay for mitoxantrone in plasma using electrochemical detection.J Chromatogr. 1987 Sep 4;420(1):81-8. doi: 10.1016/0378-4347(87)80157-3. J Chromatogr. 1987. PMID: 3667832
-
Analysis of buprenorphine in rat plasma using a solid-phase extraction technique and high-performance liquid chromatography with electrochemical detection.J Pharmacol Toxicol Methods. 1997 Mar;37(2):75-81. doi: 10.1016/s1056-8719(97)00001-4. J Pharmacol Toxicol Methods. 1997. PMID: 9174982
-
Simultaneous determination of haloperidol and its reduced metabolite in serum and plasma by isocratic liquid chromatography with electrochemical detection.Clin Chem. 1983 Apr;29(4):624-8. Clin Chem. 1983. PMID: 6831688
Cited by
-
Pharmacokinetics and bioavailability of benperidol in schizophrenic patients after intravenous and two different kinds of oral application.Psychopharmacology (Berl). 1994 Dec;116(4):457-63. doi: 10.1007/BF02247478. Psychopharmacology (Berl). 1994. PMID: 7701049 Clinical Trial.