. 2007 Feb;3(1):112-4.
doi: 10.1007/s11420-006-9026-z.

CT evaluation of total hip arthroplasty complication: dissociation of acetabular component

Affiliations

CT evaluation of total hip arthroplasty complication: dissociation of acetabular component

Eric A Bogner et al. HSS J. 2007 Feb.
No abstract available

PubMed Disclaimer

Figures

Fig. 1
Fig. 1
Anteroposterior view of the pelvis clearly demonstrates the dislodgement and dislocation of the acetabular component; however, the presence of a periprosthetic fracture is uncertain
Fig. 2
Fig. 2
Coronal reformatted CT image demonstrates the dislocated prosthesis. Viewing CT images in multiple orthogonal planes helps to diminish the regional metallic artifacts and improves diagnostic quality
Fig. 3
Fig. 3
Axial CT image viewed with soft tissue windows demonstrates the dissociated acetabular component, displaced posteriorly (arrow)
Fig. 4
Fig. 4
Axial CT scan demonstrates the dislocated prosthesis in addition to fractures through the quadrilateral plate and anterior wall (arrows)
Fig. 5
Fig. 5
Axial CT image demonstrates an additional fracture through the posterior wall (arrow)
Fig. 6
Fig. 6
Anteroposterior (AP) radiograph of the pelvis after revision arthroplasty placement

References

    1. {'text': '', 'ref_index': 1, 'ids': [{'type': 'DOI', 'value': '10.1055/s-2006-934219', 'is_inner': False, 'url': 'https://doi.org/10.1055/s-2006-934219'}, {'type': 'PubMed', 'value': '16514583', 'is_inner': True, 'url': 'https://pubmed.ncbi.nlm.nih.gov/16514583/'}]}
    2. Buckwalter KA, Parr JA, Choplin RH, Capello WN (2006) Multichannel CT imaging of orthopedic hardware and implants. Semin Musculoskelet Radiol 10(1):86–97 - PubMed
    1. {'text': '', 'ref_index': 1, 'ids': [{'type': 'DOI', 'value': '10.1097/01.rli.0000086495.96457.54', 'is_inner': False, 'url': 'https://doi.org/10.1097/01.rli.0000086495.96457.54'}, {'type': 'PubMed', 'value': '14627894', 'is_inner': True, 'url': 'https://pubmed.ncbi.nlm.nih.gov/14627894/'}]}
    2. Mahnken AH, Raupach R, Wildberger JE, Jung B, Heussen N, Flohr TG, Gunther RW, Schaller S (2003) A new algorithm for metal artifact reduction in computed tomography: in vitro and in vivo evaluation after total hip replacement. Invest Radiol 38(12):769–775 - PubMed
    1. {'text': '', 'ref_index': 1, 'ids': [{'type': 'DOI', 'value': '10.1007/s00402-006-0163-0', 'is_inner': False, 'url': 'https://doi.org/10.1007/s00402-006-0163-0'}, {'type': 'PubMed', 'value': '16810554', 'is_inner': True, 'url': 'https://pubmed.ncbi.nlm.nih.gov/16810554/'}]}
    2. Marx A, von Knoch M, Pfortner J, Wiese M, Saxler G (2006) Misinterpretation of cup anteversion in total hip anthroplasty using planar radiography. Arch Orthop Trauma Surg 126(7):487-492 - PubMed
    1. {'text': '', 'ref_index': 1, 'ids': [{'type': 'DOI', 'value': '10.1016/j.ejrad.2005.10.003', 'is_inner': False, 'url': 'https://doi.org/10.1016/j.ejrad.2005.10.003'}, {'type': 'PubMed', 'value': '16289687', 'is_inner': True, 'url': 'https://pubmed.ncbi.nlm.nih.gov/16289687/'}]}
    2. Kalteis T, Handel M, Herold T, Perlick L, Paetzel C, Grifka J (2006) Position of the acetabular cup: accuracy of radiographic calculation compared to CT-based measurement. Eur J Radiol 58(2):294–300 - PubMed
    1. {'text': '', 'ref_index': 1, 'ids': [{'type': 'DOI', 'value': '10.1080/10929080500178032', 'is_inner': False, 'url': 'https://doi.org/10.1080/10929080500178032'}, {'type': 'PubMed', 'value': '16199380', 'is_inner': True, 'url': 'https://pubmed.ncbi.nlm.nih.gov/16199380/'}]}
    2. Blendea S, Eckman K, Jaramaz B, Levison TJ, Digioia AM 3rd (2005) Measurements of acetabular cup position and pelvic spatial orientation after total hip arthroplasty using computed tomography/radiography matching. Comput Aided Surg 10(1):37–43 - PubMed