Cardiac resynchronization therapy: application of imaging to optimize patient selection and assess response
- PMID: 18752761
- DOI: 10.1007/s11897-008-0020-2
Cardiac resynchronization therapy: application of imaging to optimize patient selection and assess response
Abstract
Cardiac resynchronization therapy (CRT) has been shown to be effective for advanced heart failure and discoordinate wall motion, although the nonresponse rate for patients meeting standard CRT criteria remains about 30%. Although electrical delay (wide QRS) is commonly used to select candidates, recent data show that direct measures of mechanical dyssynchrony rather than surrogate -electrical measurements improve the identification of potential responders. This observation has stimulated the pursuit of imaging-based methods for characterizing dyssynchrony. Echocardiographic techniques have played a major role in this regard, but their accuracy and reliability have recently been scrutinized in multicenter clinical trials. This has shifted attention toward newer advanced echo methods and cardiac magnetic resonance imaging (CMR). Although CMR has a number of advantages over echocardiography for the assessment of dyssynchrony, these methods are relatively underdeveloped and not used widely clinically. This paper highlights imaging modalities for assessing wall motion and various methods for integrating the output from these complex imaging-based datasets into simple indices of dyssynchrony. Further, we investigate the role of imaging not only to improve selection of CRT responders but also to define CRT response.
Similar articles
-
Cardiac magnetic resonance assessment of mechanical dyssynchrony.Curr Opin Cardiol. 2008 Sep;23(5):440-6. doi: 10.1097/HCO.0b013e32830b3865. Curr Opin Cardiol. 2008. PMID: 18670254 Review.
-
Usefulness of echocardiographic dyssynchrony in patients with borderline QRS duration to assist with selection for cardiac resynchronization therapy.JACC Cardiovasc Imaging. 2010 Feb;3(2):132-40. doi: 10.1016/j.jcmg.2009.09.020. JACC Cardiovasc Imaging. 2010. PMID: 20159638
-
Assessment of mechanical dyssynchrony in cardiac resynchronization therapy.Dan Med J. 2014 Dec;61(12):B4981. Dan Med J. 2014. PMID: 25441737 Review.
-
Presence of extensive LV remodeling limits the benefits of CRT in patients with intraventricular dyssynchrony.JACC Cardiovasc Imaging. 2011 Oct;4(10):1067-76. doi: 10.1016/j.jcmg.2011.07.006. JACC Cardiovasc Imaging. 2011. PMID: 21999865
-
Cardiac resynchronization therapy: role of patient selection.Curr Cardiol Rep. 2006 Sep;8(5):336-42. doi: 10.1007/s11886-006-0072-4. Curr Cardiol Rep. 2006. PMID: 16956448 Review.
Cited by
-
Undersampled cine 3D tagging for rapid assessment of cardiac motion.J Cardiovasc Magn Reson. 2012 Aug 30;14(1):60. doi: 10.1186/1532-429X-14-60. J Cardiovasc Magn Reson. 2012. PMID: 22935509 Free PMC article.
-
Relationship Between Changes in Pulse Pressure and Frequency Domain Components of Heart Rate Variability During Short-Term Left Ventricular Pacing in Patients with Cardiac Resynchronization Therapy.Med Sci Monit. 2016 Jun 15;22:2043-9. doi: 10.12659/msm.895489. Med Sci Monit. 2016. PMID: 27305349 Free PMC article.
-
Single photon emission computed tomography (SPECT) techniques for resynchronization: phase analysis and equilibrium radionuclide angiocardiography.J Nucl Cardiol. 2011 Feb;18(1):16-20. doi: 10.1007/s12350-010-9312-5. J Nucl Cardiol. 2011. PMID: 21082297 No abstract available.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials