. 2008 Oct 1;80(19):7401-7.
doi: 10.1021/ac8010928. Epub 2008 Aug 29.

Integration of dialysis membranes into a poly(dimethylsiloxane) microfluidic chip for isoelectric focusing of proteins using whole-channel imaging detection

Affiliations

Integration of dialysis membranes into a poly(dimethylsiloxane) microfluidic chip for isoelectric focusing of proteins using whole-channel imaging detection

Junjie Ou et al. Anal Chem. .

Abstract

A poly(dimethylsiloxane) microfluidic chip-based cartridge is developed and reported here for protein analysis using isoelectic focusing (IEF)-whole-channel imaging detection (WCID) technology. In this design, commercial dialysis membranes are integrated to separate electrolytes and samples and to reduce undesired pressure-driven flow. Fused-silica capillaries are also incorporated in this design for sample injection and channel surface preconditioning. This structure is equivalent to that of a commercial fused-silica capillary-based cartridge for adapting to an IEF analyzer (iCE280 analyzer) to perform IEF-WCID. The successful integration of dialysis membranes into a microfluidic chip significantly improves IEF repeatability by eliminating undesired pressure-driven hydrodynamics and also makes sample injection much easier than that using the first-generation chip as reported recently. In this study, two microfluidic chips with a 100-microm-high, 100-microm-wide and a 200-microm-high, 50-microm-wide microchannel, respectively, were applied for qualitative and quantitative analysis of proteins. The mixture containing six pI markers with a pH range of 3-10 was successfully separated using IEF-WCID. The pH gradient exhibited a good linearity by plotting the pI value versus peak position, and the correlation coefficient reached 0.9994 and 0.9995 separately for the two chips. The separation of more complicated human hemoglobin control sample containing HbA, HbF, HbS, and HbC was also achieved. Additionally, for the quantitative analysis, a good linearity of IEF peak value versus myoglobin concentration in the range of 20-100 microg/mL was obtained.