Factors affecting the psychophysical image quality evaluation of mobile phone displays: the case of transmissive liquid-crystal displays
- PMID: 18758547
- DOI: 10.1364/josaa.25.002215
Factors affecting the psychophysical image quality evaluation of mobile phone displays: the case of transmissive liquid-crystal displays
Abstract
Display manufacturers require new data and computational models that consider the effect of ambient illumination in order to develop higher-quality displays. In this study, typical variations of small-sized mobile LCDs that exist in the real world were first simulated using a device characterization technique. In addition, psychophysical attributes (e.g., naturalness, clearness, sharpness, contrast, colorfulness, and preference) affecting the image quality evaluation process were analyzed. Consequently, naturalness and clearness were found to be the most statistically significant psychophysical attributes for modeling image quality. As the ambient-illumination level was increased, the image quality was exponentially impaired and the contribution of clearness increased.
Similar articles
-
Psychophysical analysis of monitor display functions affecting observer diagnostic performance of CT image on liquid crystal display monitors.Eur Radiol. 2005 Dec;15(12):2487-96. doi: 10.1007/s00330-005-2880-0. Epub 2005 Aug 16. Eur Radiol. 2005. PMID: 16132924
-
Ambient illumination revisited: a new adaptation-based approach for optimizing medical imaging reading environments.Med Phys. 2007 Jan;34(1):81-90. doi: 10.1118/1.2402583. Med Phys. 2007. PMID: 17278493
-
Comparison of human observer performance of contrast-detail detection across multiple liquid crystal displays.J Digit Imaging. 2005 Mar;18(1):66-77. doi: 10.1007/s10278-004-1035-1. J Digit Imaging. 2005. PMID: 15645331 Free PMC article.
-
[Image evaluation of CRT's--special reference to physical and psychophysical evaluation].Nihon Hoshasen Gijutsu Gakkai Zasshi. 2002 Jan;58(1):28-32. doi: 10.6009/jjrt.kj00003111338. Nihon Hoshasen Gijutsu Gakkai Zasshi. 2002. PMID: 12596828 Review. Japanese. No abstract available.
-
High-fidelity electronic display of digital radiographs.Radiographics. 1999 Nov-Dec;19(6):1653-69. doi: 10.1148/radiographics.19.6.g99no081653. Radiographics. 1999. PMID: 10555680 Review.
Cited by
-
A validated subjective rating of display quality: the Maryland Visual Comfort Scale.Surg Endosc. 2011 Feb;25(2):567-71. doi: 10.1007/s00464-010-1220-x. Epub 2010 Jul 30. Surg Endosc. 2011. PMID: 20686790
MeSH terms
LinkOut - more resources
Full Text Sources
Research Materials