Prediction of fluid responsiveness in acute respiratory distress syndrome patients ventilated with low tidal volume and high positive end-expiratory pressure
- PMID: 18766099
- DOI: 10.1097/CCM.0b013e318186b74e
Prediction of fluid responsiveness in acute respiratory distress syndrome patients ventilated with low tidal volume and high positive end-expiratory pressure
Abstract
Objective: Dynamic preload indicators with pulse pressure variation and stroke volume variation are superior to static indicators for predicting fluid responsiveness in mechanically ventilated patients. However, they are influenced by tidal volume and the level of positive end-expiratory pressure. The present study was designed to evaluate the clinical applicability of pulse pressure variation and stroke volume variation in predicting fluid responsiveness on acute respiratory distress syndrome patients ventilated with protective strategy (low tidal volume and high positive end-expiratory pressure).
Design: Prospective, observational study.
Setting: A 20-bed medical intensive care unit of a tertiary medical center.
Patients: Twenty-two sedated and paralyzed early acute respiratory distress syndrome patients.
Interventions: After being enrolled, central venous pressure, pulmonary capillary wedge pressure, and cardiac output index were obtained from a pulmonary artery catheter (OptiQ SvO2/CCO catheter), and intrathoracic blood volume, global end-diastolic volume, stroke volume variation, and pulse pressure variation were recorded from a PiCCOplus monitor. The whole set of hemodynamic measurements was performed before and after volume expansion with 500 mL hydroxyethyl starch (10% pentastarch 200/0.5).
Measurements and main results: Cardiac output index, central venous pressure, pulmonary capillary wedge pressure, global end-diastolic volume, and intrathoracic blood volume significantly increased, and pulse pressure variation and stroke volume variation significantly decreased after volume expansion. Baseline pulse pressure variation significantly correlated with volume expansion-induced absolute changes (r = .62), or percent changes in cardiac output index (r = .75) after volume expansion. The area under the receiver operating characteristic curve was the highest for pulse pressure variation (area under the receiver operating characteristic curve = 0.768) than other indicators. The threshold value for baseline pulse pressure variation greater than 11.8% predicted a significant positive response to volume expansion with a sensitivity of 68% and a specificity of 100%.
Conclusions: Baseline pulse pressure variation accurately predicted the fluid responsiveness in early acute respiratory distress syndrome patients. Roughly, a baseline pulse pressure variation greater than the threshold value of 12% is associated with a significant increase in cardiac output index after the end of volume expansion.
Comment in
-
Using pulse pressure variation in patients with acute respiratory distress syndrome.Crit Care Med. 2008 Oct;36(10):2946-8. doi: 10.1097/CCM.0b013e318187b6fd. Crit Care Med. 2008. PMID: 18812805 No abstract available.
-
Can pulse pressure variations really better predict fluid responsiveness than static indices of preload in patients with acute respiratory distress syndrome?Crit Care Med. 2009 Mar;37(3):1178. doi: 10.1097/CCM.0b013e3181986f85. Crit Care Med. 2009. PMID: 19237964 No abstract available.
-
Back to "belief-based medicine" because of receiver operating characteristic curves?Crit Care Med. 2009 Apr;37(4):1532-3. doi: 10.1097/CCM.0b013e31819d2f26. Crit Care Med. 2009. PMID: 19318859 No abstract available.
-
Prediction of fluid responsiveness in acute respiratory distress syndrome patients ventilated with low tidal volume and high positive end-expiratory pressure.Crit Care Med. 2009 Jun;37(6):2146. doi: 10.1097/CCM.0b013e3181a0974e. Crit Care Med. 2009. PMID: 19448491 No abstract available.
Similar articles
-
Positive end-expiratory pressure-induced functional recruitment in patients with acute respiratory distress syndrome.Crit Care Med. 2010 Jan;38(1):127-32. doi: 10.1097/CCM.0b013e3181b4a7e7. Crit Care Med. 2010. PMID: 19730254 Clinical Trial.
-
Hemodynamic impact of a positive end-expiratory pressure setting in acute respiratory distress syndrome: importance of the volume status.Crit Care Med. 2010 Mar;38(3):802-7. doi: 10.1097/CCM.0b013e3181c587fd. Crit Care Med. 2010. PMID: 19926983
-
Passive leg-raising and end-expiratory occlusion tests perform better than pulse pressure variation in patients with low respiratory system compliance.Crit Care Med. 2012 Jan;40(1):152-7. doi: 10.1097/CCM.0b013e31822f08d7. Crit Care Med. 2012. PMID: 21926581
-
Arterial pulse pressure variation predicting fluid responsiveness in critically ill patients.Shock. 2008 Oct;30 Suppl 1:18-22. doi: 10.1097/SHK.0b013e3181818708. Shock. 2008. Retraction in: Shock. 2009 May;31(5):542. doi: 10.1097/SHK.0b013e3181a2e492. PMID: 18704014 Retracted. Review.
-
Emerging trends in minimally invasive haemodynamic monitoring and optimization of fluid therapy.Eur J Anaesthesiol. 2009 Nov;26(11):893-905. doi: 10.1097/EJA.0b013e3283308e50. Eur J Anaesthesiol. 2009. PMID: 19667998 Review.
Cited by
-
Stroke volume changes induced by a recruitment maneuver predict fluid responsiveness in patients with protective ventilation in the operating theater.Medicine (Baltimore). 2016 Jul;95(28):e4259. doi: 10.1097/MD.0000000000004259. Medicine (Baltimore). 2016. PMID: 27428237 Free PMC article.
-
The role for invasive monitoring in acute lung injury.Semin Respir Crit Care Med. 2013 Aug;34(4):508-15. doi: 10.1055/s-0033-1351127. Epub 2013 Aug 11. Semin Respir Crit Care Med. 2013. PMID: 23934719 Free PMC article. Review.
-
Applied physiology at the bedside to drive resuscitation algorithms.J Cardiothorac Vasc Anesth. 2014 Dec;28(6):1642-59. doi: 10.1053/j.jvca.2014.07.005. J Cardiothorac Vasc Anesth. 2014. PMID: 25479921 Free PMC article. Review.
-
Accuracy of stroke volume variation in predicting fluid responsiveness: a systematic review and meta-analysis.J Anesth. 2011 Dec;25(6):904-16. doi: 10.1007/s00540-011-1217-1. Epub 2011 Sep 4. J Anesth. 2011. PMID: 21892779
-
Pulse pressure variation: where are we today?J Clin Monit Comput. 2011 Feb;25(1):45-56. doi: 10.1007/s10877-010-9229-1. J Clin Monit Comput. 2011. PMID: 20390324 Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical