Usefulness of Kelly clamp crushing technique during hepatic resection
- PMID: 18773102
- PMCID: PMC2518298
- DOI: 10.1080/13651820802167144
Usefulness of Kelly clamp crushing technique during hepatic resection
Abstract
Introduction: Recently, there are various kinds of parenchymal transection methods. The aim of this study is to evaluate the usefulness of the Kelly clamp crushing technique compared to ultrasonic dissector during hepatic resection.
Materials and methods: Comparisons between 10 ultrasonic dissector group and 10 Kelly clamp crushing technique group were performed by using nine items (transaction time, right lobe volume, perioperative transfusion, total bilirubin (TB), aspartate aminotransferase (AST), alanine aminotransferase (ALT), hospital stay, postoperative morbidity, in-hospital mortality).
Results: The mean transection time in the Kelly clamp crushing technique group was 27+/-15.5 mins (range 15-60) and was 48+/-7.1 mins (range 35-60) in the ultrasonic dissector group (p<0.05), and no patients received transfusion in both groups.
Conclusions: Since the Kelly clamp crushing technique shortens operative time and there is no significant difference in blood loss and in results of liver function tests compared to using the ultrasonic dissector, we propose that the Kelly clamp crushing technique should be considered as a standard method of liver resection.
Keywords: Kelly clamp crushing technique; hepatocelluar carcinoma; ultrasonic dissector.
Figures
Similar articles
-
Debakey forceps crushing technique for hepatic parenchymal transection in liver surgery: a review of 100 cases and ergonomic advantages.HPB Surg. 2014;2014:861829. doi: 10.1155/2014/861829. Epub 2014 Jun 9. HPB Surg. 2014. PMID: 25009367 Free PMC article.
-
Randomized comparison of ultrasonic vs clamp transection of the liver.Arch Surg. 2001 Aug;136(8):922-8. doi: 10.1001/archsurg.136.8.922. Arch Surg. 2001. PMID: 11485528 Clinical Trial.
-
Open hepatic parenchymal transection using ultrasonic dissection and bipolar coagulation.HPB (Oxford). 2008;10(4):265-70. doi: 10.1080/13651820802167961. HPB (Oxford). 2008. PMID: 18773097 Free PMC article.
-
Is the TissueLink dissecting sealer a better liver resection device than clamp-crushing? A meta-analysis and system review.Hepatogastroenterology. 2012 Nov-Dec;59(120):2602-8. doi: 10.5754/hge11872. Hepatogastroenterology. 2012. PMID: 22626880 Review.
-
Recent advances in techniques of liver resection.Surg Technol Int. 2004;13:71-7. Surg Technol Int. 2004. PMID: 15744678 Review.
Cited by
-
Methods to decrease blood loss during liver resection: a network meta-analysis.Cochrane Database Syst Rev. 2016 Oct 31;10(10):CD010683. doi: 10.1002/14651858.CD010683.pub3. Cochrane Database Syst Rev. 2016. PMID: 27797116 Free PMC article.
-
Gas jet transection of liver parenchima: experimental research.Hepatobiliary Surg Nutr. 2013 Jun;2(3):156-61. doi: 10.3978/j.issn.2304-3881.2013.06.09. Hepatobiliary Surg Nutr. 2013. PMID: 24570934 Free PMC article.
-
Radiofrequency-assisted versus clamp-crushing parenchyma transection in cirrhotic patients with hepatocellular carcinoma: a randomized clinical trial.Dig Dis Sci. 2013 Mar;58(3):835-40. doi: 10.1007/s10620-012-2394-y. Epub 2012 Sep 25. Dig Dis Sci. 2013. PMID: 23007732 Clinical Trial.
-
Anatomical Resection But Not Surgical Margin Width Influence Survival Following Resection for HCC, A Propensity Score Analysis.World J Surg. 2016 Jun;40(6):1429-39. doi: 10.1007/s00268-016-3421-5. World J Surg. 2016. PMID: 26817652
-
Debakey forceps crushing technique for hepatic parenchymal transection in liver surgery: a review of 100 cases and ergonomic advantages.HPB Surg. 2014;2014:861829. doi: 10.1155/2014/861829. Epub 2014 Jun 9. HPB Surg. 2014. PMID: 25009367 Free PMC article.
References
LinkOut - more resources
Full Text Sources