Accuracy and reproducibility of quantitation of left ventricular function by real-time three-dimensional echocardiography versus cardiac magnetic resonance
- PMID: 18774006
- DOI: 10.1016/j.amjcard.2008.04.062
Accuracy and reproducibility of quantitation of left ventricular function by real-time three-dimensional echocardiography versus cardiac magnetic resonance
Abstract
The aim of this study was to investigate the accuracy and reproducibility of the quantification of left ventricular (LV) function by real-time 3-dimensional echocardiography (RT3DE) using current state-of-the-art hardware and software. Compared with cardiac magnetic resonance (CMR), previous generations of hardware and software for RT3DE significantly underestimated LV volumes partly because of inherent factors such as limited spatial and temporal resolution. Also, RT3DE volumes were compared with short-axis CMR data, whereas a combined short-axis and long-axis analysis is known to be superior. Twenty-four subjects (mean age 51 +/- 12 years, 17 men) in sinus rhythm and with good to excellent 2-dimensional image quality underwent RT3DE and CMR within 1 day. The acquisition of RT3DE data was done with current state-of-the-art hardware and software. Two blinded experts performed off-line LV volume analysis. Global LV volumes were determined from semiautomated border detection on the basis of endocardial speckle tracking with biplane projections using QLAB version 6.0. Volumes derived by magnetic resonance imaging were quantified from combined short-axis and long-axis series. The volume-rate on RT3DE was 33 +/- 8 Hz (range 19 to 42). Excellent correlations were found (R2 > or = 0.97) between CMR and RT3DE for global LV end-diastolic volume, LV end-systolic volume, the LV ejection fraction, and LV phase volumes (24 phases/cardiac cycle). Bland-Altman analyses showed mean differences of -7.1 ml, -4.2 ml, 0.2%, and -5.8 ml and 95% limits of agreement of +/-19.7 ml, +/-8.3 ml, +/-6.2%, and +/-15.4 ml for global LV end-diastolic volume, LV end-systolic volume, the LV ejection fraction, and LV phase volumes, respectively. Interobserver variability was 5.2% for global LV end-diastolic volume, 6.4% for LV end-systolic volume, and 7.6% for the LV ejection fraction. In conclusion, in patients with good acoustic windows, RT3DE using state-of-the-art technology provides accurate and reproducible measurements of global LV volumes, LV volume changes over time, and the LV ejection fraction.
Similar articles
-
Quantitative assessment of left ventricular size and function: side-by-side comparison of real-time three-dimensional echocardiography and computed tomography with magnetic resonance reference.Circulation. 2006 Aug 15;114(7):654-61. doi: 10.1161/CIRCULATIONAHA.106.626143. Epub 2006 Aug 7. Circulation. 2006. PMID: 16894035 Clinical Trial.
-
Feasibility of single-beat full-volume capture real-time three-dimensional echocardiography and auto-contouring algorithm for quantification of left ventricular volume: validation with cardiac magnetic resonance imaging.J Am Soc Echocardiogr. 2011 Aug;24(8):853-9. doi: 10.1016/j.echo.2011.04.015. Epub 2011 Jun 8. J Am Soc Echocardiogr. 2011. PMID: 21645992
-
Clinical value of real-time three-dimensional echocardiography for right ventricular quantification in congenital heart disease: validation with cardiac magnetic resonance imaging.J Am Soc Echocardiogr. 2010 Feb;23(2):134-40. doi: 10.1016/j.echo.2009.12.001. J Am Soc Echocardiogr. 2010. PMID: 20152693
-
Real-Time Three-Dimensional Echocardiography: Characterization of Cardiac Anatomy and Function-Current Clinical Applications and Literature Review Update.Biores Open Access. 2017 Mar 1;6(1):15-18. doi: 10.1089/biores.2016.0033. eCollection 2017. Biores Open Access. 2017. PMID: 28303211 Free PMC article. Review.
-
Accuracy of Left Ventricular Volumes and Ejection Fraction Measurements by Contemporary Three-Dimensional Echocardiography with Semi- and Fully Automated Software: Systematic Review and Meta-Analysis of 1,881 Subjects.J Am Soc Echocardiogr. 2019 Sep;32(9):1105-1115.e5. doi: 10.1016/j.echo.2019.04.417. Epub 2019 Jun 21. J Am Soc Echocardiogr. 2019. PMID: 31230780
Cited by
-
Statistical agreement of left ventricle measurements using cardiac magnetic resonance and 2D echocardiography in ischemic heart failure.Med Sci Monit. 2012 Mar;18(3):MT19-25. doi: 10.12659/msm.882507. Med Sci Monit. 2012. PMID: 22367134 Free PMC article.
-
Prospectively gated axial CT coronary angiography: comparison of image quality and effective radiation dose between 64- and 256-slice CT.Eur Radiol. 2010 May;20(5):1124-31. doi: 10.1007/s00330-009-1652-7. Epub 2009 Nov 14. Eur Radiol. 2010. PMID: 19915848
-
Quantification of left ventricular volumes and function in anesthetized beagles using real-time three-dimensional echocardiography: 4D-TomTec™ analysis versus 4D-AutLVQ™ analysis in comparison with cardiac magnetic resonance imaging.BMC Vet Res. 2015 Oct 12;11:260. doi: 10.1186/s12917-015-0568-5. BMC Vet Res. 2015. PMID: 26459280 Free PMC article.
-
Reliability of myocardial perfusion gated SPECT for the reproducible evaluation of resting left ventricular functional parameters in long-term follow-up.Eur J Nucl Med Mol Imaging. 2010 Aug;37(9):1722-9. doi: 10.1007/s00259-010-1444-y. Eur J Nucl Med Mol Imaging. 2010. PMID: 20393711
-
Central role of real-time three-dimensional echocardiography in the assessment of intracardiac thrombi.Int J Cardiovasc Imaging. 2010 Jun;26(5):519-26. doi: 10.1007/s10554-010-9593-4. Epub 2010 Feb 5. Int J Cardiovasc Imaging. 2010. PMID: 20131007
MeSH terms
LinkOut - more resources
Full Text Sources