Assessment of fluctuating velocities in disturbed cardiovascular blood flow: in vivo feasibility of generalized phase-contrast MRI
- PMID: 18777557
- DOI: 10.1002/jmri.21475
Assessment of fluctuating velocities in disturbed cardiovascular blood flow: in vivo feasibility of generalized phase-contrast MRI
Abstract
Purpose: To evaluate the feasibility of generalized phase-contrast magnetic resonance imaging (PC-MRI) for the noninvasive assessment of fluctuating velocities in cardiovascular blood flow.
Materials and methods: Multidimensional PC-MRI was used in a generalized manner to map mean flow velocities and intravoxel velocity standard deviation (IVSD) values in one healthy aorta and in three patients with different cardiovascular diseases. The acquired data were used to assess the kinetic energy of both the mean (MKE) and the fluctuating (TKE) velocity field.
Results: In all of the subjects, both mean and fluctuating flow data were successfully acquired. The highest TKE values in the patients were found at sites characterized by abnormal flow conditions. No regional increase in TKE was found in the normal aorta.
Conclusion: PC-MRI IVSD mapping is able to detect flow abnormalities in a variety of human cardiovascular conditions and shows promise for the quantitative assessment of turbulence. This approach may assist in clarifying the role of disturbed hemodynamics in cardiovascular diseases.
Copyright (c) 2008 Wiley-Liss, Inc.
Similar articles
-
In vitro assessment of flow patterns and turbulence intensity in prosthetic heart valves using generalized phase-contrast MRI.J Magn Reson Imaging. 2010 May;31(5):1075-80. doi: 10.1002/jmri.22163. J Magn Reson Imaging. 2010. PMID: 20432341
-
Estimation of pulse wave velocity in main pulmonary artery with phase contrast MRI: preliminary investigation.J Magn Reson Imaging. 2006 Dec;24(6):1303-10. doi: 10.1002/jmri.20782. J Magn Reson Imaging. 2006. PMID: 17096389
-
On MRI turbulence quantification.Magn Reson Imaging. 2009 Sep;27(7):913-22. doi: 10.1016/j.mri.2009.05.004. Epub 2009 Jun 13. Magn Reson Imaging. 2009. PMID: 19525079
-
Flow measurement by magnetic resonance: a unique asset worth optimising.J Cardiovasc Magn Reson. 2007;9(4):723-8. doi: 10.1080/10976640701465090. J Cardiovasc Magn Reson. 2007. PMID: 17613655 Review.
-
Imaging of the thoracic aorta with time-resolved three-dimensional phase-contrast MRI: a review.Semin Thorac Cardiovasc Surg. 2008 Winter;20(4):358-64. doi: 10.1053/j.semtcvs.2008.11.013. Semin Thorac Cardiovasc Surg. 2008. PMID: 19251177 Review.
Cited by
-
The influence of the aortic valve angle on the hemodynamic features of the thoracic aorta.Sci Rep. 2016 Aug 26;6:32316. doi: 10.1038/srep32316. Sci Rep. 2016. PMID: 27561388 Free PMC article.
-
In vivo validation of numerical prediction for turbulence intensity in an aortic coarctation.Ann Biomed Eng. 2012 Apr;40(4):860-70. doi: 10.1007/s10439-011-0447-6. Epub 2011 Oct 21. Ann Biomed Eng. 2012. PMID: 22016327 Free PMC article. Clinical Trial.
-
Age-Related Vascular Changes Affect Turbulence in Aortic Blood Flow.Front Physiol. 2018 Jan 25;9:36. doi: 10.3389/fphys.2018.00036. eCollection 2018. Front Physiol. 2018. PMID: 29422871 Free PMC article.
-
Magnetic resonance measurement of turbulent kinetic energy for the estimation of irreversible pressure loss in aortic stenosis.JACC Cardiovasc Imaging. 2013 Jan;6(1):64-71. doi: 10.1016/j.jcmg.2012.07.017. JACC Cardiovasc Imaging. 2013. PMID: 23328563 Free PMC article.
-
Advances in machine learning applications for cardiovascular 4D flow MRI.Front Cardiovasc Med. 2022 Dec 9;9:1052068. doi: 10.3389/fcvm.2022.1052068. eCollection 2022. Front Cardiovasc Med. 2022. PMID: 36568555 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical