Inhibition of restenosis in femoropopliteal arteries: paclitaxel-coated versus uncoated balloon: femoral paclitaxel randomized pilot trial
- PMID: 18779447
- DOI: 10.1161/CIRCULATIONAHA.107.735985
Inhibition of restenosis in femoropopliteal arteries: paclitaxel-coated versus uncoated balloon: femoral paclitaxel randomized pilot trial
Erratum in
- Circulation. 2008 Oct 14;118(16):e670
Abstract
Background: The success of percutaneous intervention in peripheral arterial disease is limited by restenosis. The aim of the present pilot study was to evaluate a novel method of local drug delivery.
Methods and results: This randomized multicenter study with blinded reading enrolled 87 patients in Rutherford class 1 to 4 with occlusion or hemodynamically relevant stenosis, restenosis, or in-stent restenosis of femoropopliteal arteries. Treatment was performed by either conventional uncoated or paclitaxel-coated balloon catheters. The primary end point was late lumen loss at 6 months. Secondary end points included restenosis rate, ankle brachial index, Rutherford class, target lesion revascularization, and tolerance up to >18 months. Before intervention, there were no significant differences in lesion characteristics such as reference diameter (5.3+/-1.1 versus 5.2+/-1.0 mm), degree of stenosis (84+/-11% versus 84+/-16%), proportion of restenotic lesions (36% versus 33%), and mean lesion length (5.7 cm [0.8 to 22.6 cm] versus 6.1 cm [0.9 to 19.3 cm]) between treatment groups. The 6-month follow-up angiography performed in 31 of 45 and 34 of 42 patients showed less late lumen loss in the coated balloon group (0.5+/-1.1 versus 1.0+/-1.1 mm; P=0.031). The number of target lesion revascularizations was lower in the paclitaxel-coated balloon group than in control subjects (3 of 45 versus 14 of 42 patients; P=0.002). Improvement in Rutherford class was greater in the coated balloon group (P=0.045), whereas the improvement in ankle brachial index was not different. The difference in target lesion revascularizations between treatment groups was maintained up to >18 months. No adverse events were assessed as related to balloon coating.
Conclusions: In this pilot trial, paclitaxel balloon coating caused no obvious adverse events and reduced restenosis in patients undergoing angioplasty of femoropopliteal arteries.
Trial registration: ClinicalTrials.gov NCT00472472.