Is therapy necessary after distal biceps tendon repair?
- PMID: 18784965
- PMCID: PMC2584219
- DOI: 10.1007/s11552-008-9129-8
Is therapy necessary after distal biceps tendon repair?
Abstract
The EndoButton technique of distal biceps tendon repair provides strong biomechanical fixation. This strength of fixation may allow earlier postoperative range of motion (ROM). A retrospective review of 15 male patients undergoing single incision EndoButton repairs was used. Six subjects participated in conventional supervised postoperative rehabilitation while nine subjects were allowed unrestricted ROM after 2 weeks. Final ROM, time to full ROM, and Disabilities of Arm Shoulder and Hand (DASH) scores were compared. There was a significant difference for time to full ROM (p < 0.05). The mean time to full ROM was 8.67 weeks for the supervised therapy group and 4.38 weeks for the unrestricted group. There were no reruptures in either group. There were no significant differences in final ROM or DASH scores. These data suggest that unrestricted ROM results in a quicker return to full ROM without an increased risk of rerupture.
Similar articles
-
A functional analysis of distal biceps tendon repair: single-incision Endobutton technique vs. two-incision modified Boyd-Anderson technique.Phys Sportsmed. 2016;44(1):59-62. doi: 10.1080/00913847.2016.1129260. Epub 2015 Dec 30. Phys Sportsmed. 2016. PMID: 26641953
-
Treatment of distal biceps tendon ruptures using a single-incision technique and a Bio-Tenodesis screw.Orthopedics. 2010 Jul 13;33(7):477. doi: 10.3928/01477447-20100526-09. Orthopedics. 2010. PMID: 20608629 Clinical Trial.
-
Chronic distal biceps avulsion treated with suture button.J Shoulder Elbow Surg. 2020 Aug;29(8):1548-1553. doi: 10.1016/j.jse.2020.01.103. Epub 2020 May 4. J Shoulder Elbow Surg. 2020. PMID: 32381475
-
Single- versus double-incision technique for the treatment of distal biceps tendon rupture.Bone Joint J. 2020 Dec;102-B(12):1608-1617. doi: 10.1302/0301-620X.102B12.BJJ-2020-0822.R2. Bone Joint J. 2020. PMID: 33249900
-
Distal biceps tendon repair and posterior interosseous nerve injury: clinical results and a systematic review of the literature.Med Glas (Zenica). 2021 Feb 1;18(1):196-201. doi: 10.17392/1303-21. Med Glas (Zenica). 2021. PMID: 33480223
Cited by
-
Retrospective Study on the Risk of Nerve Injury After Distal Biceps Tendon Repair Using Cortical Button.Cureus. 2023 Aug 15;15(8):e43512. doi: 10.7759/cureus.43512. eCollection 2023 Aug. Cureus. 2023. PMID: 37719623 Free PMC article.
-
FUNCTIONAL OUTCOMES AFTER DISTAL BICEPS BRACHII REPAIR: A CASE SERIES.Int J Sports Phys Ther. 2016 Dec;11(6):962-970. Int J Sports Phys Ther. 2016. PMID: 27904798 Free PMC article.
-
Clinical Outcomes and Complications of Cortical Button Distal Biceps Repair: A Systematic Review of the Literature.J Sports Med (Hindawi Publ Corp). 2016;2016:3498403. doi: 10.1155/2016/3498403. Epub 2016 Jul 21. J Sports Med (Hindawi Publ Corp). 2016. PMID: 27525303 Free PMC article. Review.
-
Progressive Loading in a Strongman Following Distal Biceps Repair: Re-Thinking Load Progression - A Case Report.Int J Sports Phys Ther. 2022 Nov 1;17(7):1430-1441. doi: 10.26603/001c.39796. eCollection 2022. Int J Sports Phys Ther. 2022. PMID: 36518828 Free PMC article.
-
Biomechanical analysis suggests early rehabilitation is possible after single-incision EndoButton distal biceps repair with FiberWire.Knee Surg Sports Traumatol Arthrosc. 2011 Jun;19(6):1019-22. doi: 10.1007/s00167-010-1348-1. Epub 2010 Dec 15. Knee Surg Sports Traumatol Arthrosc. 2011. PMID: 21161173
References
-
- Agins HJ, Chess JL, Hoekstra DV, Teitge RA. Rupture of the distal insertion of the biceps brachii tendon. Clin Orthop Relat Res 1988. (234):34–8. - PubMed
-
- {'text': '', 'ref_index': 1, 'ids': [{'type': 'DOI', 'value': '10.1016/S1058-2746(00)90040-5', 'is_inner': False, 'url': 'https://doi.org/10.1016/s1058-2746(00)90040-5'}, {'type': 'PubMed', 'value': '10810691', 'is_inner': True, 'url': 'https://pubmed.ncbi.nlm.nih.gov/10810691/'}]}
- Bain GI, Prem H, Heptinstall RJ, Verhellen R, Paix D. Repair of distal biceps tendon rupture: a new technique using the Endobutton. J Shoulder Elbow Surg 2000;9(2):120–6. doi:10.1016/S1058-2746(00)90040-5. - PubMed
-
- {'text': '', 'ref_index': 1, 'ids': [{'type': 'PubMed', 'value': '3972865', 'is_inner': True, 'url': 'https://pubmed.ncbi.nlm.nih.gov/3972865/'}]}
- Baker BE, Bierwagen D. Rupture of the distal tendon of the biceps brachii. Operative versus non-operative treatment. J Bone Jt Surg Am 1985;67(3):414–7. - PubMed
-
- {'text': '', 'ref_index': 1, 'ids': [{'type': 'PubMed', 'value': '15010168', 'is_inner': True, 'url': 'https://pubmed.ncbi.nlm.nih.gov/15010168/'}]}
- Balabaud L, Ruiz C, Nonnenmacher J, Seynaeve P, Kehr P, Rapp E. Repair of distal biceps tendon ruptures using a suture anchor and an anterior approach. J Hand Surg Br 2004;29(2):178–82. doi:10.1016/j.jhsb.2003.07.002. - PubMed
-
- {'text': '', 'ref_index': 1, 'ids': [{'type': 'DOI', 'value': '10.1016/S1058-2746(00)90059-4', 'is_inner': False, 'url': 'https://doi.org/10.1016/s1058-2746(00)90059-4'}, {'type': 'PubMed', 'value': '10888167', 'is_inner': True, 'url': 'https://pubmed.ncbi.nlm.nih.gov/10888167/'}]}
- Bell RH, Wiley WB, Noble JS, Kuczynski DJ. Repair of distal biceps brachii tendon ruptures. J Shoulder Elbow Surg 2000;9(3):223–6. doi:10.1016/S1058-2746(00)90059-4. - PubMed
LinkOut - more resources
Full Text Sources