Prediction of sublayer depth in turbid media using spatially offset Raman spectroscopy
- PMID: 18785759
- DOI: 10.1021/ac801219a
Prediction of sublayer depth in turbid media using spatially offset Raman spectroscopy
Abstract
We demonstrate experimentally the feasibility of monitoring the depth of optically thick layers within turbid media using spatially offset Raman spectroscopy (SORS) in combination with multivariate analysis. The method uses the deep penetration capability of SORS to characterize significantly thicker (by at least a factor of 2) layers than possible with conventional Raman spectroscopy. Typical relative accuracies were between 5 and 10%. The incorporation of depth information into a SORS experiment as an additional dimension allows pure spectra of each individual layer to be resolved using three-dimensional multivariate techniques (parallel factor analysis, PARAFAC) to accuracies comparable with the results of a two-dimensional analysis.
Similar articles
-
Deep subsurface Raman spectroscopy of turbid media by a defocused collection system.Appl Spectrosc. 2007 Oct;61(10):1123-7. doi: 10.1366/000370207782217770. Appl Spectrosc. 2007. PMID: 17958964
-
Numerical simulations of subsurface probing in diffusely scattering media using spatially offset Raman spectroscopy.Appl Spectrosc. 2005 Dec;59(12):1485-92. doi: 10.1366/000370205775142548. Appl Spectrosc. 2005. PMID: 16390587
-
Deep noninvasive Raman spectroscopy of turbid media.Appl Spectrosc. 2008 Nov;62(11):291A-304A. doi: 10.1366/000370208786401527. Appl Spectrosc. 2008. PMID: 19007455 Review. No abstract available.
-
Depth profiling in diffusely scattering media using Raman spectroscopy and picosecond Kerr gating.Appl Spectrosc. 2005 Feb;59(2):200-5. doi: 10.1366/0003702053085115. Appl Spectrosc. 2005. PMID: 15720761
-
Micro-scale spatially offset Raman spectroscopy for non-invasive subsurface analysis of turbid materials.Analyst. 2016 Feb 7;141(3):731-9. doi: 10.1039/c5an02129d. Epub 2015 Dec 8. Analyst. 2016. PMID: 26646435 Review.
Cited by
-
Sensitivity of coded aperture Raman spectroscopy to analytes beneath turbid biological tissue and tissue-simulating phantoms.J Biomed Opt. 2014;19(11):117001. doi: 10.1117/1.JBO.19.11.117001. J Biomed Opt. 2014. PMID: 25371979 Free PMC article.
-
Spatially Offset and Transmission Raman Spectroscopy for Determination of Depth of Inclusion in Turbid Matrix.Anal Chem. 2019 Jul 16;91(14):8994-9000. doi: 10.1021/acs.analchem.9b01222. Epub 2019 Jun 27. Anal Chem. 2019. PMID: 31246425 Free PMC article.
-
Determination of thickness of thin turbid painted over-layers using micro-scale spatially offset Raman spectroscopy.Philos Trans A Math Phys Eng Sci. 2016 Dec 13;374(2082):20160049. doi: 10.1098/rsta.2016.0049. Philos Trans A Math Phys Eng Sci. 2016. PMID: 27799432 Free PMC article.
-
Overconstrained library-based fitting method reveals age- and disease-related differences in transcutaneous Raman spectra of murine bones.J Biomed Opt. 2013 Jul;18(7):077001. doi: 10.1117/1.JBO.18.7.077001. J Biomed Opt. 2013. PMID: 23817761 Free PMC article.
-
Analysis of subcutaneous swine fat via deep Raman spectroscopy using a fiber-optic probe.Analyst. 2020 Jul 7;145(13):4421-4426. doi: 10.1039/d0an00707b. Epub 2020 May 22. Analyst. 2020. PMID: 32441278 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources