Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2009 Aug;87(5):544-8.
doi: 10.1111/j.1755-3768.2008.01305.x. Epub 2008 Sep 11.

Anterior chamber parameters measured by the Pentacam CES after uneventful phacoemulsification in normotensive eyes

Affiliations
Free article
Comparative Study

Anterior chamber parameters measured by the Pentacam CES after uneventful phacoemulsification in normotensive eyes

Ozlenen O Uçakhan et al. Acta Ophthalmol. 2009 Aug.
Free article

Abstract

Purpose: We set out to quantify changes in the anterior chamber volume (ACV), anterior chamber depth (ACD) and anterior chamber angle (ACA) measurements obtained by the Pentacam rotating Scheimpflug camera following uneventful phacoemulsification surgery in normotensive eyes with open iridocorneal angles.

Methods: We enrolled 44 eyes of 44 consecutive patients undergoing cataract extraction in this prospective study. Patients with a history of glaucoma, angle-closure glaucoma or any other concurrent ocular disease were excluded. A detailed eye examination including intraocular pressure (IOP) measurement was performed and ACV, ACD and inferior, superior, temporal and nasal ACA measurements were obtained in each patient eye using the Pentacam Comprehensive Eye Scanner (Pentacam CES) before and 3 months after phacoemulsification and intraocular lens (IOL) implantation with temporal clear corneal incision. Data were compared using paired t-test and one-way anova.

Results: Mean preoperative ACV, ACD, ACA and IOP measurements were 164.7 +/- 49.8 mm(3), 3.0 +/- 0.8 mm, 35.7 +/- 10.2 degrees and 15.8 +/- 3.7 mmHg, respectively. Three months postoperatively, mean ACV, ACD, ACA and IOP measurements were 200.9 +/- 33.3 mm(3), 3.9 +/- 0.9 mm, 41.5 +/- 6.5 degrees and 13.2 +/- 3.9 mmHg, respectively. Postoperative mean ACV, ACD and ACA values in all four quadrants were significantly increased (p < 0.0001, p < 0.0001, p < 0.0001, respectively), whereas IOP was significantly reduced (p < 0.0001).

Conclusions: The Pentacam CES allowed very easy, fast, automatic and non-contact quantification of the anterior chamber parameters pre- and postoperatively in all patient eyes. Measurements obtained confirm that in normotensive eyes with open iridocorneal angles, the ACV and ACD increase and the ACA widens in all quadrants 3 months after uneventful phacoemulsification and IOL implantation. These changes are accompanied by a significant fall in IOP in the short term.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms

LinkOut - more resources