Comparative Study
. 2009 Feb;24(2):421-7.
doi: 10.1093/ndt/gfn518. Epub 2008 Sep 17.

High-volume haemofiltration with a new haemofiltration membrane having enhanced adsorption properties in septic pigs

Affiliations
Comparative Study

High-volume haemofiltration with a new haemofiltration membrane having enhanced adsorption properties in septic pigs

Thomas Rimmelé et al. Nephrol Dial Transplant. 2009 Feb.

Abstract

Background: High-volume haemofiltration (HVHF) has been suggested as an adjuvant treatment of septic shock due to its capacities to remove from blood both pro- and anti-inflammatory mediators involved in the sepsis syndrome. Adsorption properties of some haemofiltration membranes are also interesting with this indication because inflammatory mediators are caught in the membrane itself. The aim of this study was to determine the haemodynamic and immunological effects of a new haemofiltration membrane, which has enhanced adsorption properties due to a special surface treatment, allowing the adsorption of endotoxins.

Methods: We compared this membrane to a standard haemofiltration membrane both in vitro and in 20 sepsis-induced pigs, randomized in two groups. One group was haemofiltered with the treated membrane and the other with the standard haemofiltration membrane during 6-h HVHF sessions.

Results: At the end of the experiment, mean +/- SD crystalloids requirements (5937 +/- 1588 versus 7587 +/- 1456 ml, P = 0.026), colloids requirements (1437 +/- 320 versus 1912 +/- 538 ml, P = 0.027), lactic acidosis (pH = 7.20 +/- 0.11 versus 7.10 +/- 0.07, P = 0.026) and pulmonary arterial hypertension (MPAP = 24 +/- 7 versus 34 +/- 8 mmHg, P = 0.008) were less pronounced when HVHF was performed with the treated membrane. In addition, mean +/- SD endotoxins levels were lower in the treated membrane group after 1 hour of HVHF (1.91 +/- 1.19 versus 11.07 +/- 10.64 EU/ml, P = 0.035). Cytokines levels were not different between groups except for IL-1beta, which was slightly lower in the treated membrane group.

Conclusions: The use of a membrane with enhanced adsorption properties during a 6-h HVHF session in septic pigs improves haemodynamics compared to a standard haemofiltration membrane. These results are probably due to an efficient endotoxins and cytokines adsorption. A human study using this membrane is now necessary to confirm these results.

PubMed Disclaimer

Comment in

Publication types

MeSH terms