Abstract
This article on x-ray cone-beam CT (CBCT) acquisition provides an overview of the fundamental principles of operation of this technology and the influence of geometric and software parameters on image quality and patient radiation dose. Advantages of the CBCT system and a summary of the uses and limitations of the images produced are discussed. All current generations of CBCT systems provide useful diagnostic images. Future enhancements most likely will be directed toward reducing scan time; providing multimodal imaging; improving image fidelity, including soft tissue contrast; and incorporating task-specific protocols to minimize patient dose.
Similar articles
-
Maxillofacial cone beam computed tomography: essence, elements and steps to interpretation.Aust Dent J. 2012 Mar;57 Suppl 1:46-60. doi: 10.1111/j.1834-7819.2011.01657.x. Aust Dent J. 2012. PMID: 22376097 Review.
-
Shading correction algorithm for improvement of cone-beam CT images in radiotherapy.Phys Med Biol. 2008 Oct 21;53(20):5719-33. doi: 10.1088/0031-9155/53/20/010. Epub 2008 Sep 26. Phys Med Biol. 2008. PMID: 18824785
-
The evolution and application of dental maxillofacial imaging modalities.Dent Clin North Am. 2008 Oct;52(4):689-705, v. doi: 10.1016/j.cden.2008.05.006. Dent Clin North Am. 2008. PMID: 18805224
-
Cone beam CT in dental practice.Br Dent J. 2009 Jul 11;207(1):23-8. doi: 10.1038/sj.bdj.2009.560. Br Dent J. 2009. PMID: 19590551
-
Technical aspects of dental CBCT: state of the art.Dentomaxillofac Radiol. 2015;44(1):20140224. doi: 10.1259/dmfr.20140224. Dentomaxillofac Radiol. 2015. PMID: 25263643 Free PMC article. Review.
Cited by
-
Dose indices in dental cone beam CT and correlation with dose-area product.Dentomaxillofac Radiol. 2013;42(5):20120362. doi: 10.1259/dmfr.20120362. Epub 2013 Mar 21. Dentomaxillofac Radiol. 2013. PMID: 23520392 Free PMC article.
-
Endodontic management of a C-shaped maxillary first molar with three independent buccal root canals by using cone-beam computed tomography.Restor Dent Endod. 2012 Aug;37(3):175-9. doi: 10.5395/rde.2012.37.3.175. Epub 2012 Aug 29. Restor Dent Endod. 2012. PMID: 23429761 Free PMC article.
-
Diagnostic accuracy of MRI-CBCT fused images in assessment of clinically diagnosed internal derangement of the temporomandibular joint.Oral Radiol. 2024 Apr;40(2):226-233. doi: 10.1007/s11282-023-00727-1. Epub 2024 Jan 17. Oral Radiol. 2024. PMID: 38231306 Free PMC article.
-
The applications of cone-beam computed tomography in endodontics: a review of literature.Iran Endod J. 2015 Winter;10(1):16-25. Epub 2014 Dec 24. Iran Endod J. 2015. PMID: 25598804 Free PMC article. Review.
-
Influence of tooth position within the field of view on the intensity of cone-beam computed tomographic imaging artifacts when assessing teeth restored with various intracanal materials.Imaging Sci Dent. 2020 Jun;50(2):141-151. doi: 10.5624/isd.2020.50.2.141. Epub 2020 Jun 18. Imaging Sci Dent. 2020. PMID: 32601589 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical