Comparative evaluation of two simple diffuse reflectance models for biological tissue applications
- PMID: 18806859
- DOI: 10.1364/ao.47.004965
Comparative evaluation of two simple diffuse reflectance models for biological tissue applications
Abstract
We present a comparative evaluation of two simple diffuse reflectance models for biological tissue applications. One model is based on a widely accepted and used in biomedical optics implementation of diffusion theory, and the other one is based on a semiempirical approach derived from basic physical principles. We test the models on tissue phantoms and on human skin, utilizing a standard six-around-one optical fiber probe for light delivery and collection. We show that both models are suitable for use with an optical fiber probe and illustrate the potential, applicability, and validity range of the models.
Similar articles
-
Tutorial on diffuse light transport.J Biomed Opt. 2008 Jul-Aug;13(4):041302. doi: 10.1117/1.2967535. J Biomed Opt. 2008. PMID: 19021310
-
Scaling method for fast Monte Carlo simulation of diffuse reflectance spectra from multilayered turbid media.J Opt Soc Am A Opt Image Sci Vis. 2007 Apr;24(4):1011-25. doi: 10.1364/josaa.24.001011. J Opt Soc Am A Opt Image Sci Vis. 2007. PMID: 17361287
-
Theory of light propagation incorporating scattering and absorption in turbid media.Opt Lett. 2005 Apr 1;30(7):792-4. doi: 10.1364/ol.30.000792. Opt Lett. 2005. PMID: 15832940
-
Low-coherence enhanced backscattering: review of principles and applications for colon cancer screening.J Biomed Opt. 2006 Jul-Aug;11(4):041125. doi: 10.1117/1.2236292. J Biomed Opt. 2006. PMID: 16965153 Review.
-
Application of optical imaging and spectroscopy to radiation biology.Radiat Res. 2012 Apr;177(4):365-75. doi: 10.1667/rr2531.1. Epub 2012 Feb 23. Radiat Res. 2012. PMID: 22360397 Free PMC article. Review.
Cited by
-
Quantitative estimation of optical properties in bilayer media within the subdiffusive regime using tilted fiber-optic probe diffuse reflectance spectroscopy, part 2: probe design, realization, and experimental validation.J Biomed Opt. 2024 Oct;29(10):105002. doi: 10.1117/1.JBO.29.10.105002. Epub 2024 Oct 29. J Biomed Opt. 2024. PMID: 39474361 Free PMC article.
-
Effect of bile absorption coefficients on the estimation of liver tissue optical properties and related implications in discriminating healthy and tumorous samples.Biomed Opt Express. 2011 Feb 15;2(3):600-14. doi: 10.1364/BOE.2.000600. Biomed Opt Express. 2011. PMID: 21412465 Free PMC article.
-
Diffuse reflectance spectroscopy as a tool to measure the absorption coefficient in skin: system calibration.Lasers Med Sci. 2013 Feb;28(2):437-44. doi: 10.1007/s10103-012-1079-2. Epub 2012 Mar 13. Lasers Med Sci. 2013. PMID: 22410734
-
Estimation of biological chromophores using diffuse optical spectroscopy: benefit of extending the UV-VIS wavelength range to include 1000 to 1600 nm.Biomed Opt Express. 2010 Nov 17;1(5):1432-1442. doi: 10.1364/BOE.1.001432. Biomed Opt Express. 2010. PMID: 21258560 Free PMC article.
-
Verification of a two-layer inverse Monte Carlo absorption model using multiple source-detector separation diffuse reflectance spectroscopy.Biomed Opt Express. 2013 Dec 2;5(1):40-53. doi: 10.1364/BOE.5.000040. eCollection 2013 Dec 2. Biomed Opt Express. 2013. PMID: 24466475 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources