Simple method for accurate alignment in toric phakic and aphakic intraocular lens implantation
Abstract
A simple technique for the accurate surgical alignment of toric phakic and aphakic intraocular lenses (IOLs) is described. The mathematical relationship between toric misalignment and cylinder error is reviewed to demonstrate the importance of toric lens alignment in the setting of increased rotational stability with newer generation lenses. A formula for calculating the exact lens misalignment given a manifest cylinder is also presented.
Similar articles
-
Accuracy of toric intraocular lens implantation in cataract and refractive surgery.J Cataract Refract Surg. 2011 Aug;37(8):1394-402. doi: 10.1016/j.jcrs.2011.02.024. J Cataract Refract Surg. 2011. PMID: 21782085
-
Artisan iris-fixated toric phakic and aphakic intraocular lens implantation for the correction of astigmatic refractive error after radial keratotomy.J Cataract Refract Surg. 2007 Mar;33(3):531-5. doi: 10.1016/j.jcrs.2006.10.046. J Cataract Refract Surg. 2007. PMID: 17321407
-
Assessment of toric intraocular lens alignment by a refractive power/corneal analyzer system and slitlamp observation.J Cataract Refract Surg. 2010 Feb;36(2):222-9. doi: 10.1016/j.jcrs.2009.08.033. J Cataract Refract Surg. 2010. PMID: 20152601
-
Toric intraocular lenses: historical overview, patient selection, IOL calculation, surgical techniques, clinical outcomes, and complications.J Cataract Refract Surg. 2013 Apr;39(4):624-37. doi: 10.1016/j.jcrs.2013.02.020. J Cataract Refract Surg. 2013. PMID: 23522584 Review.
-
[Toric IOL's].J Fr Ophtalmol. 2012 Mar;35(3):220-5. doi: 10.1016/j.jfo.2011.09.006. Epub 2012 Jan 17. J Fr Ophtalmol. 2012. PMID: 22257774 Review. French.
Cited by
-
Optimizing outcomes with toric intraocular lenses.Indian J Ophthalmol. 2017 Dec;65(12):1301-1313. doi: 10.4103/ijo.IJO_810_17. Indian J Ophthalmol. 2017. PMID: 29208810 Free PMC article. Review.
-
The effect of head tilt on keratometric measurement using the IOLMaster.Eye (Lond). 2013 Dec;27(12):1411-7. doi: 10.1038/eye.2013.209. Epub 2013 Sep 20. Eye (Lond). 2013. PMID: 24051411 Free PMC article.
-
Patient Expectation, Satisfaction and Clinical Outcomes with a New Multifocal Intraocular Lens.Clin Ophthalmol. 2021 Oct 13;15:4131-4140. doi: 10.2147/OPTH.S327424. eCollection 2021. Clin Ophthalmol. 2021. PMID: 34675480 Free PMC article.
-
Evaluation of Intraocular Lens Rotational Stability in a Multicenter Clinical Trial.Clin Ophthalmol. 2021 Jul 14;15:3001-3016. doi: 10.2147/OPTH.S309214. eCollection 2021. Clin Ophthalmol. 2021. PMID: 34285467 Free PMC article.
-
A comparison of three different corneal marking methods used to determine cyclotorsion in the horizontal meridian.Clin Ophthalmol. 2017 Feb 8;11:311-315. doi: 10.2147/OPTH.S124580. eCollection 2017. Clin Ophthalmol. 2017. PMID: 28223775 Free PMC article.