ACCURATUM: improved calcium volume scoring using a mesh-based algorithm--a phantom study
- PMID: 18818930
- DOI: 10.1007/s00330-008-1181-9
ACCURATUM: improved calcium volume scoring using a mesh-based algorithm--a phantom study
Abstract
To overcome the limitations of the classical volume scoring method for quantifying coronary calcifications, including accuracy, variability between examinations, and dependency on plaque density and acquisition parameters, a mesh-based volume measurement method has been developed. It was evaluated and compared with the classical volume scoring method for accuracy, i.e., the normalized volume (measured volume/ground-truthed volume), and for variability between examinations (standard deviation of accuracy). A cardiac computed-tomography (CT) phantom containing various cylindrical calcifications was scanned using different tube voltages and reconstruction kernels, at various positions and orientations on the CT table and using different slice thicknesses. Mean accuracy for all plaques was significantly higher (p < 0.0001) for the proposed method (1.220 +/- 0.507) than for the classical volume score (1.896 +/- 1.095). In contrast to the classical volume score, plaque density (p = 0.84), reconstruction kernel (p = 0.19), and tube voltage (p = 0.27) had no impact on the accuracy of the developed method. In conclusion, the method presented herein is more accurate than classical calcium scoring and is less dependent on tube voltage, reconstruction kernel, and plaque density.
Similar articles
-
Calcium score of small coronary calcifications on multidetector computed tomography: results from a static phantom study.Eur J Radiol. 2013 Feb;82(2):e58-63. doi: 10.1016/j.ejrad.2012.09.018. Epub 2012 Oct 23. Eur J Radiol. 2013. PMID: 23092538
-
Semi-automated quantification of hepatic lesions in a phantom.Invest Radiol. 2009 Feb;44(2):82-8. doi: 10.1097/RLI.0b013e3181911ffa. Invest Radiol. 2009. PMID: 19104439
-
Evaluation of the influence of acquisition and reconstruction parameters for 16-row multidetector CT on coronary calcium scoring using a stationary and dynamic cardiac phantom.Eur Radiol. 2007 Aug;17(8):1985-94. doi: 10.1007/s00330-006-0564-z. Epub 2007 Feb 1. Eur Radiol. 2007. PMID: 17268802
-
Assessment of calcium scoring performance in cardiac computed tomography.Eur Radiol. 2003 Mar;13(3):484-97. doi: 10.1007/s00330-002-1746-y. Epub 2002 Dec 4. Eur Radiol. 2003. PMID: 12594550
-
Scoring of coronary artery calcium scans: history, assumptions, current limitations, and future directions.Atherosclerosis. 2015 Mar;239(1):109-17. doi: 10.1016/j.atherosclerosis.2014.12.040. Epub 2015 Jan 2. Atherosclerosis. 2015. PMID: 25585030 Review.
Cited by
-
Coronary calcium scoring with partial volume correction in anthropomorphic thorax phantom and screening chest CT images.PLoS One. 2018 Dec 20;13(12):e0209318. doi: 10.1371/journal.pone.0209318. eCollection 2018. PLoS One. 2018. PMID: 30571729 Free PMC article.
-
MRI and CT in the diagnosis of coronary artery disease: indications and applications.Insights Imaging. 2011 Feb;2(1):9-24. doi: 10.1007/s13244-010-0049-0. Epub 2010 Nov 23. Insights Imaging. 2011. PMID: 22347932 Free PMC article.
-
Generative models for reproducible coronary calcium scoring.J Med Imaging (Bellingham). 2022 Sep;9(5):052406. doi: 10.1117/1.JMI.9.5.052406. Epub 2022 May 31. J Med Imaging (Bellingham). 2022. PMID: 35664539 Free PMC article.