Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2008 Oct;22(20):3320-6.
doi: 10.1002/rcm.3738.

Development and validation of an analytical method for the simultaneous determination of cocaine and its main metabolite, benzoylecgonine, in human hair by gas chromatography/mass spectrometry

Affiliations

Development and validation of an analytical method for the simultaneous determination of cocaine and its main metabolite, benzoylecgonine, in human hair by gas chromatography/mass spectrometry

M Barroso et al. Rapid Commun Mass Spectrom. 2008 Oct.

Abstract

A new, simple and rapid procedure has been developed and validated for the determination of cocaine and its main metabolite, benzoylecgonine, in human hair samples. After extraction from within the hair matrix by a mixture of methanol/hydrochloric acid (2:1) at 65 degrees C for 3 h, and sample cleanup by mixed-mode solid-phase extraction (SPE), the extracts were analyzed by gas chromatography/mass spectrometry (GC/MS), after derivatization with N-methyl-N-(trimethylsilyl)trifluoroacetamide with 5% chlorotrimethylsilane. Using a sample size of only 20 mg of hair, limits of detection (LODs) and quantitation (LOQs) were, respectively, 20 and 50 pg/mg for cocaine, and 15 and 50 pg/mg for benzoylecgonine, achieving the cut-off values proposed by the Society of Hair Testing for the analysis of these compounds in hair. The method was found to be linear (weighing factor of 1/x) between the LOQ and 20 ng/mg for both compounds, with correlation coefficients ranging from 0.9974 to 0.9996 for cocaine; and from 0.9981 to 0.9994 for benzoylecgonine. Intra- and interday precision and accuracy were in conformity with the criteria normally accepted in bioanalytical method validation. The sample cleanup step presented a mean absolute recovery greater than 90% for both compounds. The developed method may be useful in forensic toxicology laboratories for the analysis of cocaine and benzoylecgonine in hair samples, taking into account its speed (only 3 h are required for the extraction of the analytes from within the matrix, whereas 5 h or even overnight extractions have been reported) and the low limits achieved (using a single quadrupole mass spectrometer, which is available in most laboratories).

PubMed Disclaimer

LinkOut - more resources