Treatment effects of intraoral appliances with conventional anchorage designs for non-compliance maxillary molar distalization: a literature review
- PMID: 18820306
- DOI: 10.1093/ejo/cjn047
Treatment effects of intraoral appliances with conventional anchorage designs for non-compliance maxillary molar distalization: a literature review
Abstract
Since the end of the 1970s, various appliances with intramaxillary anchorage for distalization of the upper molars have been described as an alternative to headgear. The major advantages of these innovative appliances are that they act permanently and are independent of patient compliance. The purpose of this study was to compare the efficiency, both quantitatively and qualitatively, of various appliance types with intramaxillary anchorage for non-compliance molar distalization. Eighty-five papers were reviewed, and 22 were identified as being suitable for inclusion. The selection was based on compliance with the following criteria: treatment group with at least 10 non-syndromal patients, conventional intraoral anchorage design using a palatal button and anchorage teeth, consistent cephalometric measurements in clinical-epidemiological studies, exact data on the course of treatment, and statistical presentation of the measured outcomes and their standard deviations. The results show that non-compliance molar distalization is possible with numerous different appliances. While molar distalization with standard pendulum appliances exhibited the largest values for dental-linear distalization, it also resulted in concurrent, substantial therapeutically undesirable distal tipping. However, specific modifications to the pendulum appliance allow achievement of almost bodily molar distalization. Different outcomes are quoted in the studies for the efficiency of loaded spring systems for distal molar movement, but it seems that the first class appliance and the palatal distal jet are more efficient than the vestibular Jones Jig. The studies identify anchorage loss as being found in the area of the incisors rather than the area of the first premolars. There was a trend for more substantial reciprocal side-effects to occur when only two teeth were included in the anchorage unit. Vertical components acting on the molars, premolars, and incisors, such as intrusion and extrusion, tended to be of secondary importance and, therefore, may be disregarded.
Similar articles
-
Efficiency of the skeletonized Pendulum K appliance for non-compliance maxillary molar distalization : A clinical pilot study.J Orofac Orthop. 2021 Nov;82(6):391-402. doi: 10.1007/s00056-021-00280-8. Epub 2021 Mar 2. J Orofac Orthop. 2021. PMID: 33651171 Free PMC article.
-
Molar distalization with pendulum appliances in the mixed dentition: effects on the position of unerupted canines and premolars.Am J Orthod Dentofacial Orthop. 2006 Mar;129(3):407-17. doi: 10.1016/j.ajodo.2005.12.004. Am J Orthod Dentofacial Orthop. 2006. PMID: 16527638
-
Efficiency of a skeletonized distal jet appliance supported by miniscrew anchorage for noncompliance maxillary molar distalization.Am J Orthod Dentofacial Orthop. 2009 Oct;136(4):578-86. doi: 10.1016/j.ajodo.2007.10.049. Am J Orthod Dentofacial Orthop. 2009. PMID: 19815162
-
Maxillary molar distalization with noncompliance intramaxillary appliances in Class II malocclusion. A systematic review.Angle Orthod. 2008 Nov;78(6):1133-40. doi: 10.2319/101507-406.1. Angle Orthod. 2008. PMID: 18947282
-
Non-compliance maxillary molar distalizing appliances: an overview of the last decade.Prog Orthod. 2012 Sep;13(2):173-84. doi: 10.1016/j.pio.2011.10.002. Epub 2012 Feb 11. Prog Orthod. 2012. PMID: 23021121 Review.
Cited by
-
Effect of clear aligners on distalization of maxillary first molars in mixed dentition and early permanent dentition: a retrospective study.Clin Oral Investig. 2025 Apr 25;29(5):274. doi: 10.1007/s00784-025-06351-z. Clin Oral Investig. 2025. PMID: 40281144
-
Comparison of treatment effects between the modified C-palatal plate and cervical pull headgear for total arch distalization in adults.Korean J Orthod. 2017 Nov;47(6):375-383. doi: 10.4041/kjod.2017.47.6.375. Epub 2017 Sep 29. Korean J Orthod. 2017. PMID: 29090125 Free PMC article.
-
Efficiency of the skeletonized Pendulum K appliance for non-compliance maxillary molar distalization : A clinical pilot study.J Orofac Orthop. 2021 Nov;82(6):391-402. doi: 10.1007/s00056-021-00280-8. Epub 2021 Mar 2. J Orofac Orthop. 2021. PMID: 33651171 Free PMC article.
-
Class II, Division 1 Angle malocclusion with severe proclination of maxillary incisors.Dental Press J Orthod. 2016 Jan-Feb;21(1):101-9. doi: 10.1590/2177-6709.21.1.101-109.bbo. Dental Press J Orthod. 2016. PMID: 27007768 Free PMC article.
-
Enhanced pendulum appliance utilizing temporary anchorage device-based Nance arch and modified springs for optimized molar distalization control: a case report.Angle Orthod. 2025 Jan 1;95(1):126-136. doi: 10.2319/031424-217.1. Angle Orthod. 2025. PMID: 39195351 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources