Three-dimensional fast spoiled gradient-echo dual echo (3D-FSPGR-DE) with water reconstruction: preliminary experience with a novel pulse sequence for gadolinium-enhanced abdominal MR imaging
- PMID: 18821620
- DOI: 10.1002/jmri.21545
Three-dimensional fast spoiled gradient-echo dual echo (3D-FSPGR-DE) with water reconstruction: preliminary experience with a novel pulse sequence for gadolinium-enhanced abdominal MR imaging
Abstract
Purpose: To compare three-dimensional fast spoiled gradient-echo dual-echo (3D-FSPGR-DE) with water reconstruction to conventional 3D-FSPGR for gadolinium-enhanced abdominal imaging.
Materials and methods: Sixty-five patients underwent abdominal MRI on a 1.5T GE-HDx MR scanner using gadolinium-enhanced 3D-FSPGR and 3D-FSPGR-DE imaging. Qualitatively, FSPGR-DE and 3D-FSPGR images were reviewed side by side for normal anatomic structures, artifacts, and image quality. The images were reviewed separately for abnormalities of abdominal organs. Receiver operating characteristic (ROC) curve analysis was performed. Quantitative analysis measured mean signal intensity of liver, spleen, aorta, liver lesions, and noise.
Results: Observers preferred FSPGR-DE for evaluating liver, vessels, muscles, and subcutaneous tissues. Fat suppression was superior on FSPGR-DE in 63 (0.97) and 61 (0.94) of 65 cases for two observers. FSPGR-DE showed less susceptibility artifact in 47 (0.72) and 41 (0.63) cases, better signal in edge slices in 60 (0.92) and 60 (0.92) cases, less phase artifact in 42 (0.65) and 45 (0.69) cases, and less parallel imaging artifact in 13 (0.20) and 10 (0.15) cases. Images were equivalent for depicting abdominal findings with no difference in the area under the ROC curve. FSPGR-DE images showed a 20%, 29%, and 34% increase in liver, splenic, and aortic signal, respectively, and a 45% and 62% increase in liver-lesion contrast and contrast-to-noise ratio (CNR), respectively.
Conclusion: Gadolinium-enhanced 3D-FSPGR-DE with water reconstruction provides volumetric abdominal imaging with superior image quality, more homogeneous fat suppression, reduced artifacts, and improved image signal and homogeneity.
(c) 2008 Wiley-Liss, Inc.
Similar articles
-
Fast spin-echo triple-echo Dixon: initial clinical experience with a novel pulse sequence for fat-suppressed T2-weighted abdominal MR imaging.J Magn Reson Imaging. 2009 Sep;30(3):569-77. doi: 10.1002/jmri.21880. J Magn Reson Imaging. 2009. PMID: 19711403
-
Multiecho time-resolved acquisition (META): a high spatiotemporal resolution Dixon imaging sequence for dynamic contrast-enhanced MRI.J Magn Reson Imaging. 2009 Jun;29(6):1406-13. doi: 10.1002/jmri.21750. J Magn Reson Imaging. 2009. PMID: 19425056
-
T1-weighted 3D dynamic contrast-enhanced MRI of the breast using a dual-echo Dixon technique at 3 T.J Magn Reson Imaging. 2011 Oct;34(4):842-51. doi: 10.1002/jmri.22705. Epub 2011 Jul 18. J Magn Reson Imaging. 2011. PMID: 21769987
-
Motion artifact control in body MR imaging.Magn Reson Imaging Clin N Am. 1999 May;7(2):289-301. Magn Reson Imaging Clin N Am. 1999. PMID: 10382162 Review.
-
Abdominal MR imaging at 3T.Magn Reson Imaging Clin N Am. 2006 Feb;14(1):17-26. doi: 10.1016/j.mric.2005.12.001. Magn Reson Imaging Clin N Am. 2006. PMID: 16530632 Review.
Cited by
-
ISMRM workshop on fat-water separation: insights, applications and progress in MRI.Magn Reson Med. 2012 Aug;68(2):378-88. doi: 10.1002/mrm.24369. Epub 2012 Jun 12. Magn Reson Med. 2012. PMID: 22693111 Free PMC article.
-
Diagnostic performance of 64-MDCT and 1.5-T MRI with high-resolution sequences in the T staging of gastric cancer: a comparative analysis with histopathology.Radiol Med. 2009 Oct;114(7):1065-79. doi: 10.1007/s11547-009-0455-x. Epub 2009 Sep 22. Radiol Med. 2009. PMID: 19774440
-
Preoperative and surveillance MR imaging of patients undergoing cytoreductive surgery and heated intraperitoneal chemotherapy.J Gastrointest Oncol. 2016 Feb;7(1):58-71. doi: 10.3978/j.issn.2078-6891.2015.115. J Gastrointest Oncol. 2016. PMID: 26941984 Free PMC article. Review.
-
Usefulness of two-point Dixon fat-water separation technique in gadoxetic acid-enhanced liver magnetic resonance imaging.World J Gastroenterol. 2015 Apr 28;21(16):5017-22. doi: 10.3748/wjg.v21.i16.5017. World J Gastroenterol. 2015. PMID: 25945017 Free PMC article.
-
Subminute fat-water-separated dual-echo automated spine survey iterative scan technique.AJNR Am J Neuroradiol. 2009 Nov;30(10):1840-6. doi: 10.3174/ajnr.A1619. Epub 2009 May 27. AJNR Am J Neuroradiol. 2009. PMID: 19474125 Free PMC article. Clinical Trial.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical