Ultrasonographically guided peripheral intravenous cannulation in emergency department patients with difficult intravenous access: a randomized trial
- PMID: 18824276
- DOI: 10.1016/j.annemergmed.2008.07.048
Ultrasonographically guided peripheral intravenous cannulation in emergency department patients with difficult intravenous access: a randomized trial
Abstract
Study objective: We seek to compare ultrasonographically guided peripheral intravenous access to a non-ultrasonographically guided method in a randomized trial of emergency department patients with difficult intravenous access.
Methods: A prospective cohort of patients with difficult intravenous access was established. Patients were randomized to 2 groups: (1) intravenous access obtained through an ultrasonographically guided technique or (2) intravenous access obtained through non-ultrasonographically guided methods. Outcomes measured were number of attempts after enrollment, time to cannulation from enrollment, and patient satisfaction. Groups were compared with nonparametric analysis.
Results: Fifty-nine patients were randomized. Twenty-eight patients were randomized to the ultrasonography group and 31 to the no ultrasonography group. A median of 2 further intravenous attempts was required in each group before successful cannulation, corresponding to a difference of 0 attempts (95% confidence interval [CI] 0 to 1 attempts). Time to cannulation showed a median of 39 minutes in the ultrasonography group compared with 26 minutes for the no ultrasonography group, giving a median increase of 13 minutes for the ultrasonographically guided group (95% CI -5 to 28 minutes). Patients in the ultrasonography group had a median Likert satisfaction score of 8 compared with 7 for the no ultrasonography group, giving a median increase of 1 on this scale in the ultrasonography group (95% CI 0 to 2).
Conclusion: Ultrasonographically guided peripheral intravenous cannulation did not decrease the number of attempts or the time to successful catheterization, nor did it improve patient satisfaction compared with the group that did not use ultrasonography. Superiority of ultrasonographically guided peripheral intravenous cannulation is not supported by this study.
Comment in
-
The magic wand of the ultrasound?Ann Emerg Med. 2010 Jan;55(1):130. doi: 10.1016/j.annemergmed.2009.07.032. Ann Emerg Med. 2010. PMID: 20116022 No abstract available.
-
Ultrasonographically guided peripheral intravenous cannulation.Ann Emerg Med. 2010 Sep;56(3):310-1; author reply 311. doi: 10.1016/j.annemergmed.2009.09.029. Ann Emerg Med. 2010. PMID: 20728779 No abstract available.
Similar articles
-
Ultrasonography-guided peripheral intravenous access versus traditional approaches in patients with difficult intravenous access.Ann Emerg Med. 2005 Nov;46(5):456-61. doi: 10.1016/j.annemergmed.2004.12.026. Ann Emerg Med. 2005. PMID: 16271677 Clinical Trial.
-
Ultrasonographically guided insertion of a 15-cm catheter into the deep brachial or basilic vein in patients with difficult intravenous access.Ann Emerg Med. 2007 Jul;50(1):68-72. doi: 10.1016/j.annemergmed.2007.02.003. Epub 2007 Apr 11. Ann Emerg Med. 2007. PMID: 17433498 Clinical Trial.
-
Ultrasound-guidance vs. standard technique in difficult vascular access patients by ED technicians.Am J Emerg Med. 2009 Feb;27(2):135-40. doi: 10.1016/j.ajem.2008.02.005. Am J Emerg Med. 2009. PMID: 19371518
-
Comparison of ultrasound guidance with palpation and direct visualisation for peripheral vein cannulation in adult patients: a systematic review and meta-analysis.Br J Anaesth. 2018 Aug;121(2):358-366. doi: 10.1016/j.bja.2018.04.047. Epub 2018 Jul 2. Br J Anaesth. 2018. PMID: 30032874
-
Ultrasound-guided peripheral intravenous canulation by emergency nurses: A systematic review and meta-analysis.Int Emerg Nurs. 2024 Mar;73:101422. doi: 10.1016/j.ienj.2024.101422. Epub 2024 Feb 23. Int Emerg Nurs. 2024. PMID: 38401479
Cited by
-
Development of the A-DIVA Scale: A Clinical Predictive Scale to Identify Difficult Intravenous Access in Adult Patients Based on Clinical Observations.Medicine (Baltimore). 2016 Apr;95(16):e3428. doi: 10.1097/MD.0000000000003428. Medicine (Baltimore). 2016. PMID: 27100437 Free PMC article.
-
Ultrasound-guided peripheral intravenous access in the emergency department: patient-centered survey.West J Emerg Med. 2011 Nov;12(4):475-7. doi: 10.5811/westjem.2011.3.1920. West J Emerg Med. 2011. PMID: 22224141 Free PMC article.
-
Ultrasonography in Emergency Department; a Diagnostic Tool for Better Examination and Decision-Making.Adv J Emerg Med. 2017 Dec 11;2(1):e7. doi: 10.22114/AJEM.v0i0.40. eCollection 2018 Winter. Adv J Emerg Med. 2017. PMID: 31172070 Free PMC article. Review.
-
Point-of-care ultrasound in primary care: a systematic review of generalist performed point-of-care ultrasound in unselected populations.Ultrasound J. 2019 Nov 19;11(1):31. doi: 10.1186/s13089-019-0145-4. Ultrasound J. 2019. PMID: 31749019 Free PMC article. Review.
-
Adaptive Kinematic Control of a Robotic Venipuncture Device Based on Stereo Vision, Ultrasound, and Force Guidance.IEEE Trans Ind Electron. 2017 Feb;64(2):1626-1635. doi: 10.1109/TIE.2016.2557306. Epub 2016 Apr 21. IEEE Trans Ind Electron. 2017. PMID: 28111492 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical