Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2008 Oct 1;33(21):2310-5.
doi: 10.1097/BRS.0b013e31818047f2.

Blood conservation techniques in spinal deformity surgery: a retrospective review of patients refusing blood transfusion

Affiliations
Comparative Study

Blood conservation techniques in spinal deformity surgery: a retrospective review of patients refusing blood transfusion

Samuel Abraham Joseph Jr et al. Spine (Phila Pa 1976). .

Abstract

Study design: A retrospective review.

Objective: To review the effectiveness of blood conservation techniques in the spinal fusion of patients that refuse blood transfusion; specifically the Jehovah's witnesses population.

Summary of background: Spinal surgery can be challenging in patients refusing blood transfusion. There is paucity in the literature examining blood conservation techniques in spinal surgery.

Methods: The radiographic and medical records of 19 Jehovah's witnesses patients who underwent spinal deformity surgery at a single institution between 2000 and 2003 were reviewed. Patients were assessed for excessive blood loss (EBL), deformity correction, operative time, perioperative complications, and hospital stay. At latest follow-up (mean, 40 months; range, 8-76) the patients were examined for radiographic fusion, progression and complications.

Results: Spinal fusion was attempted in 19 patients, with a mean age of 17 years (range, 10-36 years). All 19 patients were identified through the "Bloodless Surgery Program." Hypotensive anesthesia, hemodilution, and cell saver was employed for all 19 cases. Erythropoietin with supplemental iron was used in 15 patients. Aprotinin was used in 3 patients. EBL and blood returned by cell saver averaged 855 and 341 mL, respectively. Operative times average 315 minutes. The average drop in hemoglobin from after surgery was 3.1 g/dL. There were 2 intraoperative complications: (i) transient loss of somatosensory evoked potential/motor evoked potential signals; and (ii) one surgery abandoned due to EBL. The average spinal deformity correction was 58%. There were 3 postoperative complications, none related to their refusal of a transfusion. 17 patients were available for radiographic and clinic follow-up of at least 24 months. All displayed radiographic fusion without progression.

Conclusion: These blood conservation techniques allow satisfactory completion of deformity surgery on those patients not willing to be transfused and without major anesthetic or medical complications.