Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2008 Oct;122(4):825-30.
doi: 10.1542/peds.2007-3667.

Systematic review of digital imaging screening strategies for retinopathy of prematurity

Affiliations

Systematic review of digital imaging screening strategies for retinopathy of prematurity

Alex R Kemper et al. Pediatrics. 2008 Oct.

Abstract

Background: Retinal imaging with remote interpretation could decrease the number of diagnostic eye examinations that premature infants need for the detection of retinopathy of prematurity and thus decrease the time demand on the relatively small pool of ophthalmologists who perform retinopathy of prematurity examinations.

Objective: Our goal was to review systematically the evidence regarding the reliability, validity, safety, costs, and benefits of retinal imaging to screen infants who are at risk for retinopathy of prematurity.

Methods: We searched Medline, the Cochrane library, CINAHL, and the bibliographies of all relevant articles. All English-language studies regardless of design with primary data about our study questions were included. We excluded (1) studies that only included subjects with retinopathy of prematurity, (2) hypothetical models other than cost-effectiveness studies, and (3) validity studies without sufficient data to determine prevalence, sensitivity, and specificity or that only evaluated subjects for 1 component of retinopathy of prematurity (eg, plus disease only).

Results: Studies of only 1 retinal imaging device (RetCam [Clarity Medical Systems, Inc, Pleasanton, CA]) met the inclusion criteria. There was a wide range in reported sensitivity, but specificity was high. There were several important limitations noted, including the eye as the unit of analysis instead of the individual or variations in the criteria for determining a true-positive or true-negative screening result. The risk of retinal hemorrhage resulting from imaging is low, and systemic effects (eg, bradycardia, hypertension, decreased oxygen saturation) are mild. No generalizable cost-effectiveness data were found.

Conclusions: The evidence base is not sufficient to recommend that retinal imaging be routinely adopted by NICUs to identify infants who have serious retinopathy of prematurity.

PubMed Disclaimer

Comment in

Similar articles

Cited by

References

    1. Early Treatment for Retinopathy of Prematurity Cooperative Group. Revised indications for the treatment of retinopathy of prematurity: results of the early treatment for retinopathy of prematurity randomized trial. Arch Ophthalmol. 2003;121(12):1684–1694. - PubMed
    1. American Academy of Pediatrics, Section on Ophthalmology; American Academy of Ophthalmology; American Association for Pediatric Ophthalmology and Strabismus. Screening examination of premature infants for retinopathy of prematurity [published correction appears in Pediatrics. 2006;2118(2): 1324] Pediatrics. 2006;117(2):572–576. - PubMed
    1. Kemper AR, Wallace DK. Neonatologists’ practices and experiences in arranging retinopathy of prematurity screening services. Pediatrics. 2007;120(3):527–531. - PMC - PubMed
    1. Bulpitt CJ, Baum JD. Retinal photography in the newborn. Arch Dis Child. 1969;44(236):499–503. - PMC - PubMed
    1. Watzke RC, Robertson JE, Jr, Palmer EA, Wallace PR, Evans MS, Soldevilla JE. Photographic grading in the retinopathy of prematurity cryotherapy trial. Arch Ophthalmol. 1990;108(7):950–955. - PubMed

Publication types

MeSH terms