. 2009 May;89(2):325-334.
doi: 10.1002/jbm.b.31219.

Selective Laser Melting: a regular unit cell approach for the manufacture of porous, titanium, bone in-growth constructs, suitable for orthopedic applications

Affiliations

Selective Laser Melting: a regular unit cell approach for the manufacture of porous, titanium, bone in-growth constructs, suitable for orthopedic applications

Lewis Mullen et al. J Biomed Mater Res B Appl Biomater. 2009 May.

Abstract

In this study, a novel porous titanium structure for the purpose of bone in-growth has been designed, manufactured and evaluated. The structure was produced by Selective Laser Melting (SLM); a rapid manufacturing process capable of producing highly intricate, functionally graded parts. The technique described utilizes an approach based on a defined regular unit cell to design and produce structures with a large range of both physical and mechanical properties. These properties can be tailored to suit specific requirements; in particular, functionally graded structures with bone in-growth surfaces exhibiting properties comparable to those of human bone have been manufactured. The structures were manufactured and characterized by unit cell size, strand diameter, porosity, and compression strength. They exhibited a porosity (10-95%) dependant compression strength (0.5-350 Mpa) comparable to the typical naturally occurring range. It is also demonstrated that optimized structures have been produced that possesses ideal qualities for bone in-growth applications and that these structures can be applied in the production of orthopedic devices.

PubMed Disclaimer

References

REFERENCES

    1. Ryan G,Pandit A,Apatsidis DP. Fabrication methods of porous metals for use in orthopaedic applications. Biomaterials 2006; 27: 2651-2670.
    1. Huiskes R,Weinans H,Van Rietbergen B. The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials. Clin Orthop Relat Res 1992; 274: 124-134.
    1. Sumner DR,Galante JO. Determinants of stress shielding: Design versus materials versus interface. Clin Orthop Relat Res 1992; 274: 202-212.
    1. Van Lenthe GH,De Waal Malefijt MC,Huiskes R. Stress shielding after total knee replacement may cause bone resorption in the distal femur. J Bone Joint Surg B 1997; 79: 117-122.
    1. Buehler KO,Venn-Watson E,D'Lima DD,Colwell CWJr. The Press-Fit Condylar total knee system: 8- to 10-year results with a posterior cruciate-retaining design. J Arthroplasty 2000; 15: 698-701.

Publication types