Technical principles of dual source CT
- PMID: 18842371
- DOI: 10.1016/j.ejrad.2008.08.013
Technical principles of dual source CT
Abstract
During the past years, multi-detector row CT (MDCT) has evolved into clinical practice with a rapid increase of the number of detector slices. Today's 64 slice CT systems allow whole-body examinations with sub-millimeter resolution in short scan times. As an alternative to adding even more detector slices, we describe the system concept and design of a CT scanner with two X-ray tubes and two detectors (mounted on a CT gantry with a mechanical offset of 90 degrees) that has the potential to overcome limitations of conventional MDCT systems, such as temporal resolution for cardiac imaging. A dual source CT (DSCT) scanner provides temporal resolution equivalent to a quarter of the gantry rotation time, independent of the patient's heart rate (83 ms at 0.33 s rotation time). In addition to the benefits for cardiac scanning, it allows to go beyond conventional CT imaging by obtaining dual energy information if the two tubes are operated at different voltages. Furthermore, we discuss how both acquisition systems can be used to add the power reserve of two X-ray tubes for long scan ranges and obese patients. Finally, future advances of DSCT are highlighted.
Similar articles
-
CT technology overview: 64-slice and beyond.Radiol Clin North Am. 2009 Jan;47(1):1-11. doi: 10.1016/j.rcl.2008.10.004. Radiol Clin North Am. 2009. PMID: 19195530 Review.
-
X-ray computed tomography.Phys Med Biol. 2006 Jul 7;51(13):R29-43. doi: 10.1088/0031-9155/51/13/R03. Epub 2006 Jun 20. Phys Med Biol. 2006. PMID: 16790909 Review.
-
Noninvasive imaging of the coronary arteries using a 64-row multidetector CT scanner: initial clinical experience and radiation dose concerns.Radiol Med. 2007 Feb;112(1):31-46. doi: 10.1007/s11547-007-0118-8. Epub 2007 Feb 22. Radiol Med. 2007. PMID: 17310293 English, Italian.
-
[On the way to isotopic spatial resolution: technical principles and applications of 16-slice CT].Radiologe. 2005 Jul;45(7):608-17. doi: 10.1007/s00117-003-0944-1. Radiologe. 2005. PMID: 16059657 Review. German.
-
Principles of CT and CT technology.J Nucl Med Technol. 2007 Sep;35(3):115-28; quiz 129-30. doi: 10.2967/jnmt.107.042978. J Nucl Med Technol. 2007. PMID: 17823453 Review.
Cited by
-
Medical evaluation and pharmacotherapeutical strategies in management of urolithiasis.Ther Adv Urol. 2021 Feb 24;13:1756287221993300. doi: 10.1177/1756287221993300. eCollection 2021 Jan-Dec. Ther Adv Urol. 2021. PMID: 33708261 Free PMC article. Review.
-
Advanced abdominal imaging with dual energy CT is feasible without increasing radiation dose.Cancer Imaging. 2016 Jun 21;16(1):15. doi: 10.1186/s40644-016-0073-5. Cancer Imaging. 2016. PMID: 27329159 Free PMC article.
-
Automated cortical bone segmentation for multirow-detector CT imaging with validation and application to human studies.Med Phys. 2015 Aug;42(8):4553-65. doi: 10.1118/1.4923753. Med Phys. 2015. PMID: 26233184 Free PMC article.
-
Design and characterization of a spatially distributed multibeam field emission x-ray source for stationary digital breast tomosynthesis.Med Phys. 2009 Oct;36(10):4389-99. doi: 10.1118/1.3213520. Med Phys. 2009. PMID: 19928069 Free PMC article.
-
State of the art: technologies for computed tomography dose reduction.Emerg Radiol. 2010 May;17(3):209-18. doi: 10.1007/s10140-009-0850-6. Epub 2009 Nov 20. Emerg Radiol. 2010. PMID: 19936808 Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials
Miscellaneous