Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1991 Sep;19(9):1132-7.
doi: 10.1097/00003246-199109000-00007.

Noninvasive optimization of left ventricular filling using esophageal Doppler

Affiliations
Comparative Study

Noninvasive optimization of left ventricular filling using esophageal Doppler

M Singer et al. Crit Care Med. 1991 Sep.

Abstract

Objective: To confirm whether the descending aortic blood flow velocity waveform variable of flow time corrected for heart rate, measured using an esophageal Doppler transducer, can be used for noninvasive optimization of left ventricular (LV) filling.

Setting: ICU and operating theater.

Subjects: Forty-three mechanistically ventilated patients in the ICU or undergoing cardiothoracic surgery in whom a pulmonary arterial catheter was in situ.

Interventions: LV preload was a) increased from hypovolemic states (pulmonary arterial occlusion pressure [PAOP] less than 8 mm Hg) by fluid challenge, b) decreased from normovolemic states (PAOP 10 to 15 mm Hg) by either iv nitrates or intravascular fluid loss, and c) decreased from heart failure or fluid overload states (PAOP greater than 20 mm Hg) by iv nitrates. No other maneuver was performed concurrently.

Measurements and main results: Descending aortic blood flow was measured by an esophageal Doppler transducer. Corrected flow time was calculated by dividing systolic flow time by the square root of the cycle time. PAOP and corrected flow time increased after fluid challenges in hypovolemic states, and decreased when LV preload was decreased from normovolemic states. However, when preload was decreased from overload states, PAOP always decreased, but the corrected flow time usually increased before any subsequent decrease. The greatest value of corrected flow time corresponded with the maximal stroke volume seen.

Conclusions: Esophageal Doppler measurement of aortic blood flow can be used for rapid, noninvasive optimization of LV filling in mechanically ventilated patients.

PubMed Disclaimer

Publication types

LinkOut - more resources