Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2009 Dec;72(3):432-9.
doi: 10.1016/j.ejrad.2008.09.005. Epub 2008 Oct 11.

Focal liver lesion detection and characterization: comparison of non-contrast enhanced and SPIO-enhanced diffusion-weighted single-shot spin echo echo planar and turbo spin echo T2-weighted imaging

Affiliations
Comparative Study

Focal liver lesion detection and characterization: comparison of non-contrast enhanced and SPIO-enhanced diffusion-weighted single-shot spin echo echo planar and turbo spin echo T2-weighted imaging

Kenneth Coenegrachts et al. Eur J Radiol. 2009 Dec.

Abstract

Purpose: To compare lesion conspicuity and image quality between single-shot spin echo echo planar imaging (SS SE-EPI) before, immediately and 5min after intravenous (IV) injection of superparamagnetic iron oxide (SPIO) for detecting and characterizing focal liver lesions (FLLs).

Materials and methods: Twenty-five patients suspected for colorectal liver metastases were prospectively included. Lesion detection and characterization were compared between all SS SE-EPI and T2-weighted turbo spin echo (T2w TSE) sets (two-sided Fisher's exact test). Image quality and lesion conspicuity were compared for SS SE-EPI sets using rank order statistic (RIDIT). Reference standard comprised of surgery, biopsy and/or follow-up.

Results: Reference standard demonstrated 18 benign and 43 malignant FLLs. Best lesion detection (p<0.05) was achieved with non-contrast-enhanced SS SE-EPI. Lesion characterization was best using all T2w TSE sequences. Best image quality and lesion conspicuity (p<0.05) was achieved with non-contrast-enhanced SS SE-EPI.

Conclusion: Non-contrast-enhanced SS SE-EPI was best for lesion detection. SS SE-EPI sequences were not useful for lesion characterization (differentiation between benign and malignant lesions). Unenhanced SS SE-EPI did not allow differentiation especially as many benign FLLs were hyperintense on the highest b-value images. Combining unenhanced and SPIO-enhanced SS SE-EPI performed better but still was not clinically useful due to variable degree of uptake and vascular pooling of SPIO for (especially) benign FLLs. T2w TSE with SPIO-enhancement was needed for characterization.