Alternate and new brominated flame retardants detected in U.S. house dust
- PMID: 18853808
- DOI: 10.1021/es801070p
Alternate and new brominated flame retardants detected in U.S. house dust
Abstract
Due to the voluntary withdrawals and/or bans on the use of two polybrominated diphenyl ether (PBDE) commercial mixtures, an increasing number of alternate flame retardant chemicals are being introduced in commercial applications. To determine if these alternate BFRs are present in indoor environments, we analyzed dust samples collected from 19 homes in the greater Boston, MA area during 2006. Using pure and commercial standards we quantified the following brominated flame retardant chemicals using GC/ECNI-MS methods: hexabromocyclododecane (sigma HBCD), bis(2,4,6,-tribromphenoxy)ethane (BTBPE), decabromodiphenyl ethane (DBDPE), and the brominated components found in Firemaster 550 (FM 550): 2-ethylhexyl 2,3,4,5-tetrabromobenzoate (TBB) and (2-ethylhexyl)tetrabromophthalate (TBPH), the latter compound being a brominated analogue of di(2-ethylhexyl)phthalate (DEHP). The concentrations of all compounds were log-normally distributed and the largest range in concentrations was observed for HBCD (sum of all isomers), with concentrations ranging from <4.5 ng/g to a maximum of 130,200 ng/g with a median value of 230 ng/g. BTBPE ranged from 1.6 to 789 ng/g with a median value of 30 ng/g and DBDPE ranged from <10.0 to 11,070 ng/g with a median value of 201 ng/g. Of the FM 550 components, TBB ranged from <6.6 to 15,030 ng/g with a median value of 133 ng/g; whereas TBPH ranged from 1.5 to 10,630 ng/g with a median value of 142 ng/g. Furthermore, the ratio of TBB/TBPH present in the dust samples ranged from 0.05 to 50 (average 4.4), varying considerably from the ratio observed in the FM 550 commercial mixture (4:1 by mass), suggesting different sources with different chemical compositions, and/or differential fate and transport within the home. Analysis of paired dust samples collected from different rooms in the same home suggests HBCD, TBB, and TBPH are higher in dust from the main living area compared to dust collected in bedrooms; however, BTBPE and DBDPE levels were comparable between rooms. This study highlights the fact that numerous types of brominated flame retardants are present in indoor environments, raising questions about exposure to mixtures of these contaminants.
Comment in
-
New flame retardants detected in indoor and outdoor environments.Environ Sci Technol. 2008 Sep 15;42(18):6778. doi: 10.1021/es802145r. Environ Sci Technol. 2008. PMID: 18853785 No abstract available.
-
Comment on "Alternate and new brominated flame retardants detected in U.S. house dust".Environ Sci Technol. 2008 Dec 15;42(24):9453-4; author reply 9455-6. doi: 10.1021/es802281d. Environ Sci Technol. 2008. PMID: 19174931 No abstract available.
-
Discontinued pajama flame retardant detected in baby products and house dust.Environ Sci Technol. 2009 Oct 1;43(19):7159. doi: 10.1021/es902480t. Environ Sci Technol. 2009. PMID: 19848114 No abstract available.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous