Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2008 Oct;31(10):1423-31.

Portable monitoring and autotitration versus polysomnography for the diagnosis and treatment of sleep apnea

Affiliations
Randomized Controlled Trial

Portable monitoring and autotitration versus polysomnography for the diagnosis and treatment of sleep apnea

Richard B Berry et al. Sleep. 2008 Oct.

Abstract

Study objectives: To compare a clinical pathway using portable monitoring (PM) for diagnosis and unattended autotitrating positive airway pressure (APAP) for selecting an effective continuous positive airway pressure (CPAP) with another pathway using polysomnography (PSG) for diagnosis and treatment of obstructive sleep apnea (OSA).

Design: Randomized parallel group

Setting: Veterans Administration Medical Center

Patients: 106 patients with daytime sleepiness and a high likelihood of having OSA MEASUREMENTS AND RESULTS: The AHI in the PM-APAP group was 29.2 +/- 2.3/h and in the PSG group was 36.8 +/- 4.8/h (P= NS). Patients with an AHI > or = 5 were offered CPAP treatment. Those accepting treatment (PM-APAP 45, PSG 43) were begun on CPAP using identical devices at similar mean pressures (11.2 +/- 0.4 versus 10.9 +/- 0.5 cm H2O). At a clinic visit 6 weeks after starting CPAP, 40 patients in the PM-APAP group (78.4% of those with OSA and 88.8% started on CPAP) and 39 in the PSG arm (81.2% of those with OSA and 90.6% of those started on CPAP) were using CPAP treatment (P = NS). The mean nightly adherence (PM-APAP: 5.20 +/- 0.28 versus PSG: 5.25 +/- 0.38 h/night), decrease in Epworth Sleepiness Scale score (-6.50 +/- 0.71 versus -6.97 +/- 0.73), improvement in the global Functional Outcome of Sleep Questionnaire score (3.10 +/- 0.05 versus 3.31 +/- 0.52), and CPAP satisfaction did not differ between the groups.

Conclusions: A clinical pathway utilizing PM and APAP titration resulted in CPAP adherence and clinical outcomes similar to one using PSG.

PubMed Disclaimer

Figures

Figure 1
Figure 1
The patient flow through the PM-APAP arm of the study is illustrated. The round circles show the number of patients in that part of the study.
Figure 2
Figure 2
The patient flow through the PSG arm of the study is illustrated. The round circles show the number of patients in that part of the study.
Figure 3
Figure 3
Individual CPAP adherence values (all nights) are shown for the PM-APAP and PSG study arms.

References

    1. Flemons WW, Douglas NJ, Kuna ST, Rodenstein DO, Wheatley J. Access to diagnosis and treatment of patients with suspected sleep apnea. Am J Respir Crit Care Med. 2004;169:668–72. - PubMed
    1. Kushida CA, Littner MR, Morgenthaler T, et al. Practice parameters for the indications for polysomnography and related procedures: an update for 2005. Sleep. 2005;28:499–521. - PubMed
    1. Kushida CA, Littner MR, Hirschkowitz M, et al. Practice parameters for the use of continuous and bilevel positive airway pressure devices to treat adult patients with sleep-related breathing disorders. Sleep. 2006;29:375–80. - PubMed
    1. Gay P, Weaver T, Loube D, Iber C. Evaluation of positive airway pressure treatment for sleep related breathing disorders in adults. Sleep. 2006;29:381–401. - PubMed
    1. Flemons WW, Littner MR, Rowley JA, Gay P, et al. Home diagnosis of sleep apnea: a systematic review of the literature: an evidence based review. Chest. 2003;124:1543–79. - PubMed

Publication types