Xenon anesthesia impairs hepatic oxygenation and perfusion in healthy pigs
- PMID: 18854792
Xenon anesthesia impairs hepatic oxygenation and perfusion in healthy pigs
Abstract
Background: Over the last 15 years, there has been growing interest in the noble gas xenon as a new inhalational anesthetic. This is due to its favorable pharmacological properties such as short onset and offset, as well as its hemodynamic stability. However, most volatile anesthetics appear to play an important role in the multi-factorial etiology of perioperative liver injury by decreasing liver blood flow with a subsequent reduction of hepatic oxygen supply. However, the effects of the anesthetic gas xenon on hepatic perfusion and oxygenation have not been completely investigated.
Methods: Following ethical approval, 18 anesthetized and acutely monitored pigs were randomly assigned to the two following groups: 9 animals received xenon anesthesia in increasing inspiratory concentrations of 0%, 20%, 50%, and 65% in addition to their basic intravenous anesthesia; 9 animals served as a control group. Measurement points for systemic and regional hemodynamic and oxygenation parameters were performed 30 min after changing the xenon concentration.
Results: Xenon elicited dose-dependent systemic hemodynamic changes such that the mean arterial pressure did not change, while the heart rate and cardiac output decreased by about 30%, thereby indicating an increase in the systemic vascular resistance. Portal venous blood flow decreased, while hepatic arterial blood flow was unchanged. The oxygen supply of the liver was reduced, but not the rate of indocyanine plasma disappearance from the liver. Furthermore, the increase of liver surface pO2 to systemic hyperoxia was absent, and hepatic lactate uptake was reduced.
Conclusion: Xenon, in addition to basic intravenous anesthesia, elicited a decrease in heart rate and cardiac output and an increase in mean arterial pressure. Similar to volatile anesthetics, xenon does reduce portal venous flow and influences hepatic tissue oxygenation. In contrast, hepatic arterial blood flow remains stable in the presence of xenon, and no changes in the hepatic arterial buffer responses were evident. Xenon does affect hepatic perfusion and oxygenation.
Comment in
-
The potential of Xenon anesthesia could be patient dependent.Minerva Anestesiol. 2008 Oct;74(10):509-10. Minerva Anestesiol. 2008. PMID: 18854791 No abstract available.
Similar articles
-
Effects of systemically applied clonidine on intestinal perfusion and oxygenation in healthy pigs during general anaesthesia and laparotomy.Eur J Anaesthesiol. 2005 Nov;22(11):879-86. doi: 10.1017/S0265021505001493. Eur J Anaesthesiol. 2005. PMID: 16225726
-
Effects of xenon anaesthesia on intestinal oxygenation in acutely instrumented pigs.Br J Anaesth. 2004 Dec;93(6):833-41. doi: 10.1093/bja/aeh271. Epub 2004 Oct 1. Br J Anaesth. 2004. PMID: 15465844
-
Differences in effects of isoflurane and enflurane on splanchnic oxygenation and hepatic metabolism in the pig.Anesth Analg. 1990 Sep;71(3):258-67. Anesth Analg. 1990. PMID: 2393109
-
Xenon: recent developments and future perspectives.Minerva Anestesiol. 2009 Jan-Feb;75(1-2):37-45. Epub 2008 May 15. Minerva Anestesiol. 2009. PMID: 18475253 Review.
-
[Hepatic circulation and anesthesia].Masui. 1991 Feb;40(2):166-78. Masui. 1991. PMID: 2020091 Review. Japanese.
Cited by
-
Noble Gases Therapy in Cardiocerebrovascular Diseases: The Novel Stars?Front Cardiovasc Med. 2022 Mar 16;9:802783. doi: 10.3389/fcvm.2022.802783. eCollection 2022. Front Cardiovasc Med. 2022. PMID: 35369316 Free PMC article. Review.
-
Xenon: a solution for anesthesia in liver disease?Hepat Mon. 2012 Nov;12(11):e8437. doi: 10.5812/hepatmon.8437. Epub 2012 Nov 20. Hepat Mon. 2012. PMID: 23300498 Free PMC article. No abstract available.
-
Gasotransmitters and noble gases in cardioprotection: unraveling molecular pathways for future therapeutic strategies.Basic Res Cardiol. 2024 Aug;119(4):509-544. doi: 10.1007/s00395-024-01061-1. Epub 2024 Jun 15. Basic Res Cardiol. 2024. PMID: 38878210 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources