Comparative Study
. 1991 Jul;29(7):1422-8.
doi: 10.1128/jcm.29.7.1422-1428.1991.

Comparison of the autoSCAN-W/A rapid bacterial identification system and the Vitek AutoMicrobic system for identification of gram-negative bacilli

Affiliations
Comparative Study

Comparison of the autoSCAN-W/A rapid bacterial identification system and the Vitek AutoMicrobic system for identification of gram-negative bacilli

M A Pfaller et al. J Clin Microbiol. 1991 Jul.

Abstract

The autoSCAN-W/A (W/A; Baxter MicroScan, West Sacramento, Calif.) with the new fluorometric Rapid Neg Combo 1 (RNC) panel is a fully automated fluorometric system for identification of both enteric and nonenteric gram-negative bacilli within 2 h. We compared the W/A with the Vitek AutoMicrobic System (Vitek AMS; Vitek Systems, Inc., Hazelwood, Mo.) for identification of 383 clinical isolates of gram-negative bacilli. The API 20E (Analytab Products, Plainview, N.Y.) and conventional biochemical testing were used as the reference systems. The W/A correctly identified 336 isolates (87.7%) to the species level and classified an additional 29 isolates (7.6%) as correct with low probability (overall identification = 95.3%); the Vitek AMS correctly identified 355 isolates (92.7%) to the species level and classified an additional 8 isolates (2.1%) as correct with low probability (overall identification = 94.8%). A common set of 134 isolates of gram-negative bacilli was tested in both participating laboratories as a means of assessing interlaboratory agreement with both the W/A and the Vitek AMS. The overall agreements between the two laboratories were 86% with the W/A and 92% with the Vitek AMS. The W/A performed comparably to the Vitek AMS for identification of most gram-negative bacilli, actually exceeding the Vitek AMS for identification of nonenteric bacilli. Rapid time to identification and a high level of automation make the W/A an attractive system for clinical microbiology laboratories.

PubMed Disclaimer

Similar articles

Cited by

References

    1. J Clin Microbiol. 1988 Aug;26(8):1586-8 - PubMed
    1. J Clin Microbiol. 1981 Jan;13(1):120-5 - PubMed
    1. J Clin Microbiol. 1988 Oct;26(10):2054-8 - PubMed
    1. J Clin Microbiol. 1984 Sep;20(3):509-14 - PubMed
    1. J Clin Microbiol. 1986 Feb;23(2):251-7 - PubMed

Publication types

MeSH terms

LinkOut - more resources