Uncoated polyethylene RM acetabular component versus Müller cemented acetabular component. A 4- to 8-year follow-up study
- PMID: 1892714
- DOI: 10.1007/BF00571058
Uncoated polyethylene RM acetabular component versus Müller cemented acetabular component. A 4- to 8-year follow-up study
Abstract
Comparable patient populations with 160 uncoated RM acetabular cups and 263 cemented Müller standard acetabular cups were submitted to survival-time analysis in a retrospective study with a mean follow-up of 5.3 years for the RM cup and 6.1 years for the Müller cup. After 7-8 years 12% of the RM cups and 4% of the Müller cups had been exchanged, 40% and 15% respectively were loose. The poor performance of the RM cups is ascribed to additional external polyethylene wear, which leads to the formation of granulomas and destroys the weight-bearing osseous structures. Similar granulomas also develop on the proximal stem and thus endanger the same.
Similar articles
-
Aseptic loosening of straight- and curved-stem Müller femoral prostheses.Arch Orthop Trauma Surg. 1991;110(4):190-4. doi: 10.1007/BF00571057. Arch Orthop Trauma Surg. 1991. PMID: 1892713
-
[Migration analysis of cemented Müller polyethylene acetabular cups versus cement-free Zweymüller screw-attached acetabular cups].Z Orthop Ihre Grenzgeb. 2000 Jan-Feb;138(1):46-51. doi: 10.1055/s-2000-10112. Z Orthop Ihre Grenzgeb. 2000. PMID: 10730363 German.
-
[Failure of the polyethylene cups directly implanted into bone. A study of 32 Freeman cups after 9 years of followup (6-12 years)].Rev Chir Orthop Reparatrice Appar Mot. 1998 Nov;84(8):700-4. Rev Chir Orthop Reparatrice Appar Mot. 1998. PMID: 10192120 French.
-
New polymer materials in total hip arthroplasty. Evaluation with radiostereometry, bone densitometry, radiography and clinical parameters.Acta Orthop Suppl. 2005 Feb;76(315):3-82. Acta Orthop Suppl. 2005. PMID: 15790289 Review.
-
Choosing the socket in total hip arthroplasty.Can J Surg. 1995 Feb;38 Suppl 1:S46-8. Can J Surg. 1995. PMID: 7874628 Review.
Cited by
-
Osteolysis around uncoated polyethylene acetabular cups : A seven- to nine-year follow-up of 79 hips.Eur J Orthop Surg Traumatol. 1995 Dec;5(2):113-8. doi: 10.1007/BF02716252. Eur J Orthop Surg Traumatol. 1995. PMID: 24193330
-
A prospective study of the migration of two acetabular components. PCA versus RM cups.Int Orthop. 1994 Feb;18(1):23-8. doi: 10.1007/BF00180174. Int Orthop. 1994. PMID: 8021064 Clinical Trial.
-
Is there evidence for a superior method of socket fixation in hip arthroplasty? A systematic review.Int Orthop. 2011 Aug;35(8):1109-18. doi: 10.1007/s00264-011-1234-6. Epub 2011 Mar 15. Int Orthop. 2011. PMID: 21404024 Free PMC article.