Comparative Study
. 1991 Oct;18(4):982-9.
doi: 10.1016/0735-1097(91)90757-z.

The double-balloon and Inoue techniques in percutaneous mitral valvuloplasty: comparative results in a series of 232 cases

Affiliations
Free article
Comparative Study

The double-balloon and Inoue techniques in percutaneous mitral valvuloplasty: comparative results in a series of 232 cases

J P Bassand et al. J Am Coll Cardiol. 1991 Oct.
Free article

Abstract

Immediate hemodynamic results of percutaneous mitral valvuloplasty were compared in two consecutive series of unselected patients from the same institution undergoing valvuloplasty with the double-balloon (161 patients) or the Inoue balloon (71 patients) technique. Before valvuloplasty, the patient series were comparable with regard to average age, gender repartition and most clinical, electrocardiographic, X-ray and hemodynamic variables. Poor anatomic forms of mitral stenosis were equally distributed in both series (41% vs. 45%, p = NS). The magnitude of mitral valve area increase and of mean mitral gradient decrease during percutaneous mitral valvuloplasty did not differ significantly in the Inoue balloon and double-balloon series (mean +/- SEM 1.1 +/- 0.2 to 1.95 +/- 0.5 and 1.0 +/- 0.2 to 1.97 +/- 0.5 cm2, respectively, for mitral valve area and 12 +/- 3 to 5 +/- 2 and 13 +/- 4 to 5 +/- 2 mm Hg, respectively, for mean mitral gradient). Four cases of 3+ mitral regurgitation occurred in the Inoue balloon series and 7 in the double-balloon series (p = NS). A good immediate result--defined as mitral valve area greater than or equal to 1.5 cm2 with greater than or equal to 25% in mitral valve area gain and mitral regurgitation less than 2+ at the end of the procedure--was observed in 78% of patients in both series. Three cases of tamponade due to chamber perforation and 14 cases of transient air embolism in the right coronary system due to balloon rupture were observed in the double-balloon series.(ABSTRACT TRUNCATED AT 250 WORDS)