Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2009 Jan;37(1):130-5.
doi: 10.1177/0363546508323749. Epub 2008 Oct 28.

Immediate active range of motion after modified 2-incision repair in acute distal biceps tendon rupture

Affiliations

Immediate active range of motion after modified 2-incision repair in acute distal biceps tendon rupture

Akin Cil et al. Am J Sports Med. 2009 Jan.

Abstract

Background: Different rehabilitation protocols have been used after repair of distal biceps ruptures.

Purpose: This study investigates the safety of immediate active range of motion protocol after modified 2-incision distal biceps tendon repair in acute ruptures.

Study design: Case series; Level of evidence, 4.

Materials and methods: Twenty-one patients with a minimum follow-up of 2 years were participants in this study. After repair, the upper extremities were placed in a sling for 1 to 2 days and then immediate active range of motion was started. For the first 6 weeks, the elbow was allowed activities of daily living as tolerated by the patient with a 1-lb weight-lifting restriction. Elbow range of motion, isometric and dynamic flexion, and supination strengths were recorded and Disabilities of the Arm, Shoulder and Hand (DASH) scores were obtained.

Results: Mean follow-up extension was 0 degrees and mean follow-up flexion was 141 degrees on the operated side, with supination of 74 degrees and pronation of 75 degrees. The mean DASH score for 21 patients was 3.6 +/- 3.6 (range, 0-11.4). The mean follow-up isometric flexion strength was found to be 5% (P = .411), and the power (dynamic strength) of flexion was 12% greater on the operated side (P = .046). However, follow-up isometric supination strength was 9% less on the involved side than on the noninvolved side (P = .030), and the power of supination was 11% less on the operated side (P = .007). There were no tendon reruptures at follow-up, determined by physical examination.

Conclusion: A modified 2-incision distal biceps repair allows a safe immediate active range of motion protocol with early return of nearly full range of motion and strength, without any clinically significant disability.

PubMed Disclaimer

LinkOut - more resources