Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2008 Nov;32(11):864-9.
doi: 10.1111/j.1525-1594.2008.00643.x.

Nitric oxide in conjunction with milrinone better stabilized pulmonary hemodynamics after Fontan procedure

Affiliations
Randomized Controlled Trial

Nitric oxide in conjunction with milrinone better stabilized pulmonary hemodynamics after Fontan procedure

Jiming Cai et al. Artif Organs. 2008 Nov.

Abstract

Inhaled nitric oxide (iNO) has been used for patients with increased pulmonary vascular resistance (PVR) shortly after Fontan operation, but repeat deterioration of PVR during or shortly after its withdrawal remains a major concern. Milrinone, a phosphodiesterase type 3 (PDE3) inhibitor, can also reduce PVR for postoperative patients with pulmonary hypertension. We hypothesized that iNO, in conjunction with milrinone, can provide additive benefits for pulmonary hemodynamics and reduce the occurrence of iNO withdrawal failure/rebound. Thirty-one patients with marked elevation of transpulmonary pressure gradient (TPG, >10 mm Hg) or central venous pressure (CVP, >15 mm Hg) after modified fenestrated Fontan operation were prospectively randomized into two groups, that is, group iNO (iNO at approximately 10 ppm, n = 15) and group iNO + Mil (iNO at approximately 10 ppm and milrinone at 0.5 microg/kg/min, n = 16). Hemodynamics, arterial blood oxygenation, and occurrence of withdrawal failure/rebound were compared between the two groups. Combined application of iNO and milrinone resulted in (i) more significant decrement of CVP (19.6 +/- 3.5% in group iNO + Mil vs. 15.2 +/- 4.6% in group iNO, P < 0.05) and TPG (18.2 +/- 4.8% in group iNO + Mil vs. 15.3 +/- 2.6% in group iNO, P < 0.05), (ii) more significant increment of systolic systemic arterial pressure (8.7 +/- 2.7% in group iNO + Mil vs. 5.2 +/- 3.1% in group iNO, P < 0.05), and (iii) more significant improvement of arterial oxygen saturation (9.3 +/- 3.2% in group iNO + Mil vs. 6.8 +/- 2.8% in group iNO, P < 0.01). Occurrence of iNO withdrawal failure during its weaning or rebound after its discontinuation was significantly lower in group iNO + Mil. The combined use of iNO and milrinone provided additive benefits as compared with exclusive use of iNO for patients with elevated PVR after Fontan procedure.

PubMed Disclaimer

Publication types

LinkOut - more resources