Differential pulse voltammetric enzyme-linked immunoassay for the determination of Helicobacter pylori specific immunoglobulin G (IgG) antibody
- PMID: 18966807
- DOI: 10.1016/s0039-9140(96)02120-0
Differential pulse voltammetric enzyme-linked immunoassay for the determination of Helicobacter pylori specific immunoglobulin G (IgG) antibody
Abstract
A differential pulse voltammetric enzyme-linked immunoassay for the determination of helicobacter pylori (H. pylori) specific IgG antibody in human serum has been developed. The method is based on coupling the oxidation reaction of 3,3',5,5'-tetramethylbenzidine (TMB)-H(2)O(2) that is catalysed by horseradish peroxidase-IgG(HRP-IgG) conjugate with the electro-reduction of the enzymatic product to measure the activity of HRP-IgG. The latter reaction exhibits a sensitive differential pulse voltammetric response at 0.1 V (versus Ag AgCl ) in pH 4.0 acetate buffer solution. So, the H. pylori specific IgG antibody could be detected. The detection limit of present method for H. pylori specific IgG antibody was 1.0 units ml(-1), which was about seven times lower than that obtained by traditional spectrophotometric ELISA procedure.
Similar articles
-
Sensitive detection of a plant virus by electrochemical enzyme-linked immunoassay.Fresenius J Anal Chem. 2000 Aug;367(7):667-71. doi: 10.1007/s002160000423. Fresenius J Anal Chem. 2000. PMID: 11221932
-
Detection of TMV with ODA-H(2)O(2)-HRP voltammetric enzyme-linked immunoassay system.Talanta. 1998 Dec;47(5):1129-37. doi: 10.1016/s0039-9140(98)00192-1. Talanta. 1998. PMID: 18967418
-
Detection of prostate specific antigen with 3,4-diaminobenzoic acid (DBA)-H(2)O(2)-HRP voltammetric enzyme-linked immunoassay system.Talanta. 2007 Jun 15;72(4):1487-93. doi: 10.1016/j.talanta.2007.01.063. Epub 2007 Feb 9. Talanta. 2007. PMID: 19071788
-
Investigation of voltammetric enzyme-linked immunoassay based on a new system of HAP-H2O2-HRP.Talanta. 2008 Jun 30;76(1):122-7. doi: 10.1016/j.talanta.2008.02.024. Epub 2008 Mar 4. Talanta. 2008. PMID: 18585252
-
Detection of ferritin in human serum with a MAP-H(2)O(2)-HRP voltammetric enzyme-linked immunoassay system.Talanta. 1999 Aug 23;50(1):95-101. doi: 10.1016/s0039-9140(99)00105-8. Talanta. 1999. PMID: 18967699
Cited by
-
Sensitive electrochemical detection of horseradish peroxidase at disposable screen-printed carbon electrode.Electroanalysis. 2008 Aug 5;20(18):2040. doi: 10.1002/elan.200804287. Electroanalysis. 2008. PMID: 20148182 Free PMC article.
-
Non-invasive diagnostic tests for Helicobacter pylori infection.Cochrane Database Syst Rev. 2018 Mar 15;3(3):CD012080. doi: 10.1002/14651858.CD012080.pub2. Cochrane Database Syst Rev. 2018. PMID: 29543326 Free PMC article.
-
Overview on the Development of Electrochemical Immunosensors by the Signal Amplification of Enzyme- or Nanozyme-Based Catalysis Plus Redox Cycling.Molecules. 2024 Jun 12;29(12):2796. doi: 10.3390/molecules29122796. Molecules. 2024. PMID: 38930860 Free PMC article. Review.
LinkOut - more resources
Full Text Sources
Other Literature Sources