Simultaneous detection of monovalent anions and cations using all solid-state contact PVC membrane anion and cation-selective electrodes as detectors in single column ion chromatography
Abstract
The overall efficiency of ion chromatographic procedures allows the possibility of routine separation and detection of common inorganic and organic anions and cations at low levels in a simultaneous system. A simple and rapid independent separation, and sensitive simultaneous detection of monovalent common anions and cations were achieved using 2 mM copper sulfate, (at pH: 5.40), as eluent with low cell-volume potentiometric detectors. This was established using all-solid state contact, tubular, PVC-matrix membrane anion and cation-selective electrodes in series as detectors with mixed-bed ion-exchange column in ion chromatography. The developed method is reproducible and highly selective to monovalent anions and cations, and takes less than 8 min. Under all operation conditions, the detection limits of the developed method, for potassium, rubidium, cesium, thallium(I), nitrite, nitrate, benzoate and bromide, were of the order of tens of ppb, for sodium, ammonium, chloroacetate, cyanate and chloride ions, values were of the order of hundreds of ppb for an injected volume of 20 mul. The method was flexible since most of anions do not interfere the detection of cations and most of cations do not affect the detection of anions, so that the method can be applied to many sample types e.g. environmental. The application of the method for river, sea and tap water samples were illustrated.
Similar articles
-
Simultaneous Analysis of Monovalent Anions and Cations with a Sub-Microliter Dead-Volume Flow-Through Potentiometric Detector for Ion Chromatography.J Chromatogr Sci. 2016 Apr;54(4):598-603. doi: 10.1093/chromsci/bmv193. Epub 2016 Jan 18. J Chromatogr Sci. 2016. PMID: 26786906 Free PMC article.
-
Utilization of Anion-exchange Guard Column as an Ion Chromatographic Column of Anions Including Application to Simultaneous Separation of Anions and Cations.Anal Sci. 2019 Oct 10;35(10):1117-1122. doi: 10.2116/analsci.19P146. Epub 2019 Jun 21. Anal Sci. 2019. PMID: 31231089
-
Simultaneous ion-exclusion/cation-exchange chromatography of anions and cations in acid rain waters on a weakly acidic cation-exchange resin by elution with sulfosalicylic acid.J Chromatogr A. 2000 Jul 7;884(1-2):167-74. doi: 10.1016/s0021-9673(00)00202-8. J Chromatogr A. 2000. PMID: 10917435
-
Recent progress and applications of ion-exclusion/ion-exchange chromatography for simultaneous determination of inorganic anions and cations.Anal Sci. 2012;28(9):845-52. doi: 10.2116/analsci.28.845. Anal Sci. 2012. PMID: 22975911 Review.
-
Potentiometric detection in liquid chromatographic systems: An overview.J Chromatogr A. 2019 Sep 27;1602:326-340. doi: 10.1016/j.chroma.2019.06.006. Epub 2019 Jun 4. J Chromatogr A. 2019. PMID: 31227359 Review.
Cited by
-
Addressing the Detection of Ammonium Ion in Environmental Water Samples via Tandem Potentiometry-Ion Chromatography.ACS Meas Sci Au. 2022 Jun 15;2(3):199-207. doi: 10.1021/acsmeasuresciau.1c00056. Epub 2022 Jan 20. ACS Meas Sci Au. 2022. PMID: 35726251 Free PMC article.
-
Organoleptic Analysis of Drinking Water Using an Electronic Tongue Based on Electrochemical Microsensors.Sensors (Basel). 2019 Mar 23;19(6):1435. doi: 10.3390/s19061435. Sensors (Basel). 2019. PMID: 30909583 Free PMC article.
-
Simultaneous Analysis of Monovalent Anions and Cations with a Sub-Microliter Dead-Volume Flow-Through Potentiometric Detector for Ion Chromatography.J Chromatogr Sci. 2016 Apr;54(4):598-603. doi: 10.1093/chromsci/bmv193. Epub 2016 Jan 18. J Chromatogr Sci. 2016. PMID: 26786906 Free PMC article.
-
An electronic tongue designed to detect ammonium nitrate in aqueous solutions.Sensors (Basel). 2013 Oct 18;13(10):14064-78. doi: 10.3390/s131014064. Sensors (Basel). 2013. PMID: 24145916 Free PMC article.
-
The evaluation and comparison of trigonal and linear tricationic ion-pairing reagents for the detection of anions in positive mode ESI-MS.J Am Soc Mass Spectrom. 2009 Mar;20(3):529-38. doi: 10.1016/j.jasms.2008.11.015. Epub 2008 Nov 27. J Am Soc Mass Spectrom. 2009. PMID: 19110441
LinkOut - more resources
Full Text Sources
Miscellaneous