Nickel determination in saline matrices by ICP-AES after sorption on Amberlite XAD-2 loaded with PAN
- PMID: 18967562
- DOI: 10.1016/s0039-9140(98)00339-7
Nickel determination in saline matrices by ICP-AES after sorption on Amberlite XAD-2 loaded with PAN
Abstract
In the present paper, a solid phase extraction system for separation and preconcentration of nickel (ng g(-1)) in saline matrices is proposed. It is based on the adsorption of nickel(II) ions onto an Amberlite XAD-2 resin loaded with 1-(2-pyridylazo)-2-naphthol (PAN) reagent. Parameters such as the pH effect on the nickel extraction, the effect of flow rate and sample volume on the extraction, the sorption capacity of the loaded resin, the nickel desorption from the resin and the analytical characteristics of the procedure were studied. The results demonstrate that nickel(II) ions, in the concentration range 0.10-275 microg l(-1), and pH 6.0-11.5, contained in a sample volume of 25-250 ml, can be extracted by using 1 g Amberlite XAD-2 resin loaded with PAN reagent. The adsorbed nickel was eluted from the resin by using 5 ml 1 M hydrochloric acid solution. The extractor system has a sorption capacity of 1.87 mumol nickel per g of Amberlite XAD-2 resin loaded with PAN. The precision of the method, evaluated as the R.S.D. obtained after analyzing a series of seven replicates, was 3.9% for nickel in a concentration of 0.20 microg ml(-1). The proposed procedure was used for nickel determination in alkaline salts of analytical grade and table salt, using an inductively coupled plasma atomic emission spectroscopy technique (ICP-AES). The standard addition technique was used and the recoveries obtained revealed that the proposed procedure shows good accuracy.
Similar articles
-
Copper determination in natural water samples by using FAAS after preconcentration onto amberlite XAD-2 loaded with calmagite.Talanta. 2000 Jan 10;50(6):1253-9. doi: 10.1016/s0039-9140(99)00230-1. Talanta. 2000. PMID: 18967821
-
Preconcentration of trace metals on Amberlite XAD-4 resin coated with dithiocarbamates and determination by inductively coupled plasma-atomic emission spectrometry in saline matrices.Talanta. 2002 May 16;57(2):243-52. doi: 10.1016/s0039-9140(02)00033-4. Talanta. 2002. PMID: 18968624
-
Solid phase extraction and preconcentration of Cu(II), Pb(II), and Ni(II) in environmental samples on chemically modified Amberlite XAD-4 with a proper Schiff base.Environ Monit Assess. 2011 Feb;173(1-4):709-22. doi: 10.1007/s10661-010-1417-4. Epub 2010 Mar 18. Environ Monit Assess. 2011. PMID: 20237836
-
Preconcentration-separation of Co2+, Ni2+, Cu2+ and Cd2+ in real samples by solid phase extraction of a calix[4] resorcinarene modified Amberlite XAD-16 resin.J Hazard Mater. 2009 Dec 30;172(2-3):802-8. doi: 10.1016/j.jhazmat.2009.07.065. Epub 2009 Jul 24. J Hazard Mater. 2009. PMID: 19765894
-
New generation Amberlite XAD resin for the removal of metal ions: A review.J Environ Sci (China). 2015 May 1;31:104-23. doi: 10.1016/j.jes.2014.12.008. Epub 2015 Mar 30. J Environ Sci (China). 2015. PMID: 25968265 Review.
Cited by
-
The efficiency of Amberlite XAD-4 resin loaded with 1-(2-pyridylazo)-2-naphthol in preconcentration and separation of some toxic metal ions by flame atomic absorption spectrometry.Environ Monit Assess. 2011 Apr;175(1-4):201-12. doi: 10.1007/s10661-010-1506-4. Epub 2010 May 28. Environ Monit Assess. 2011. PMID: 20508986
-
Multi-Element Analysis Based on an Automated On-Line Microcolumn Separation/Preconcentration System Using a Novel Sol-Gel Thiocyanatopropyl-Functionalized Silica Sorbent Prior to ICP-AES for Environmental Water Samples.Molecules. 2021 Jul 24;26(15):4461. doi: 10.3390/molecules26154461. Molecules. 2021. PMID: 34361614 Free PMC article.
-
Controlled size reduction of rare earth doped nanoparticles for optical quantum technologies.RSC Adv. 2018 Nov 5;8(65):37098-37104. doi: 10.1039/c8ra07246a. eCollection 2018 Nov 1. RSC Adv. 2018. PMID: 35557813 Free PMC article.
-
Spectrofluorimetric determination of nickel (ΙΙ) with murexide.J Fluoresc. 2014 May;24(3):855-8. doi: 10.1007/s10895-014-1363-6. Epub 2014 Feb 13. J Fluoresc. 2014. PMID: 24522346
-
Heavy metal contents of refined and unrefined table salts from Turkey, Egypt and Greece.Environ Monit Assess. 2008 Aug;143(1-3):267-72. doi: 10.1007/s10661-007-9975-9. Epub 2007 Sep 16. Environ Monit Assess. 2008. PMID: 17874307
LinkOut - more resources
Full Text Sources