Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2009 Jan;36(1):65-70.
doi: 10.1111/j.1365-2842.2008.01894.x. Epub 2008 Oct 22.

In vivo spectroradiometric evaluation of colour matching errors among five shade guides

Affiliations
Comparative Study

In vivo spectroradiometric evaluation of colour matching errors among five shade guides

Q Li et al. J Oral Rehabil. 2009 Jan.

Abstract

The purpose of this study was to evaluate the colour errors of visual shade selection by five different shade guides. The maxillary left central incisors of sixty participants were visually evaluated by two groups of prosthodontists, with different clinical experience. The shade selection results were recorded and the most selected tab was determined as the resultant shade for each tooth. If totally different opinions were obtained, consensus was needed to determine the resultant shade among the observers. The colour distributions (L*, a* and b*) of each tooth and shade tab were measured using a spectroradiometer. The coverage errors (CEs) of each shade guide and colour differences (DeltaE values) between a tooth and the selected shade tabs were calculated. Two-way anova and Tukey's post hoc analysis were used to evaluate the differences of CE and DeltaE values among shade guides and clinical experience (alpha = 0.05). Coverage errors and DeltaE values in all of the five shade guide systems were all beyond the clinical threshold of 3.3 units. The consensus led to a better colour matching than that of the single decision group in Vitapan 3D-Master and Shofu NCC shade guides. A significant difference (P < 0.001) was found among DeltaE values of the shade guide system and clinical experience. In conclusion, all five of the shade guide systems used did not achieve clinically compatible shade matching. However, the Vitapan 3D Master shade guide system resulted in the lowest CEs and DeltaE values. Consensus could be helpful in enhancing the aesthetic results using Vitapan 3D Master and Shofu NCC shade guides.

PubMed Disclaimer

Comment in

Publication types

LinkOut - more resources