Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2008 Nov 1;233(9):1432-40.
doi: 10.2460/javma.233.9.1432.

Use of a balloon-expandable metallic stent for treatment of nasopharyngeal stenosis in dogs and cats: six cases (2005-2007)

Affiliations

Use of a balloon-expandable metallic stent for treatment of nasopharyngeal stenosis in dogs and cats: six cases (2005-2007)

Allyson C Berent et al. J Am Vet Med Assoc. .

Abstract

Objective: To determine outcome associated with use of a balloon-expandable metallic stent for treatment of nasopharyngeal stenosis in dogs and cats.

Design: Retrospective case series.

Animals: 3 dogs and 3 cats.

Procedures: All 6 animals had severe inspiratory stertor at initial examination. Two animals had no orifice present at the stenosis. Nasopharyngeal stenosis was diagnosed and stent size determined by use of computed tomography. A percutaneous transluminal angioplasty balloon premounted with a balloon-expandable metallic stent was placed over a guidewire, advanced through the stenotic lesion under fluoroscopic and rhinoscopic guidance, and dilated to restore patency.

Results: All animals had immediate resolution of clinical signs after stent placement. The procedure took a median of 38 minutes (range, 22 to 70 minutes). One animal with a stenosis located far caudally needed the tip of the stent resected because of hairball entrapment and exaggerated swallowing. Both animals without an orifice in the stenosis had tissue in-growth requiring a covered stent. All animals were reexamined 6 to 12 weeks after treatment via rhinoscopy, radiography, computed tomography, or a combination of techniques. All animals lacked signs of discomfort; 5 of 6 were breathing normally 12 to 28 months after the procedure.

Conclusions and clinical relevance: Transnasal balloon-expandable metallic stent placement may represent a rapid, safe, noninvasive, and effective treatment in animals with nasopharyngeal stenosis. If the stenosis is extremely caudal in the nasopharynx, serial balloon dilatation might be considered prior to stent placement. A covered stent should be considered initially if the stenosis is completely closed.

PubMed Disclaimer

MeSH terms