Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2008 Dec 19;1214(1-2):134-42.
doi: 10.1016/j.chroma.2008.10.045. Epub 2008 Nov 6.

Application of comprehensive two-dimensional gas chromatography to sterols analysis

Affiliations

Application of comprehensive two-dimensional gas chromatography to sterols analysis

Blagoj S Mitrevski et al. J Chromatogr A. .

Abstract

The applicability of comprehensive two-dimensional gas chromatography (GCxGC) for sterol analysis was investigated by separation and identification of endogenous sterols in standards, and spiked in human urine. The modulation temperature was optimized to achieve the best separation and signal enhancement. The separation pattern of trimethylsilyl (TMS) derivatives of sterols was compared on two complementary column sets. Whilst the BPX5/BPX50 column set offers better overall separation, BPX50/BPX5 provides better peak shape and sensitivity. Comparison of the identification power of GCxGC-TOFMS against both the NIST05 MS library and a laboratory created (in-house) TOFMS library was carried out on a free sterols extract of urine, derivatised and spiked at the World Anti-Doping Agency (WADA) limit of 2 ng mL(-1). The average match quality for 19 analysed sterols on the BPX50/BPX5 column set was 950/1000 when searched against the in-house library; only four were identified against the NIST05 library, at a match threshold of 800. The match quality of GCxGC-TOFMS spectra was superior to that for analysis using 1D GC-TOFMS for sterols spiked in urine at 10 ng mL(-1). An r(2)>0.997 was obtained for the concentration range between 0.25 ng mL(-1) and 10 ng mL(-1) for three selected sterols. The lowest limit of detection (LOD) was obtained for estrone (0.1 ng mL(-1)) and the highest LOD was for 5alpha-androstan-3alpha,11beta-diol-17-one, epitestosterone and cholesteryl butyrate (1 ng mL(-1)), using a match threshold of at least 800 and signal-to-noise ratio of at least 10. TOFMS coupled to GCxGC enabled satisfactory identification of sterols in urine at their LOD. A minimum acceptable match (MAM) criterion for urinary sterols using 2D retention times and TOF mass spectra is introduced. This study shows that GCxGC-TOFMS yields high specificity for steroids derived from urine, with detection limits appropriate for use in doping control.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources