Application of comprehensive two-dimensional gas chromatography to sterols analysis
- PMID: 18980770
- DOI: 10.1016/j.chroma.2008.10.045
Application of comprehensive two-dimensional gas chromatography to sterols analysis
Abstract
The applicability of comprehensive two-dimensional gas chromatography (GCxGC) for sterol analysis was investigated by separation and identification of endogenous sterols in standards, and spiked in human urine. The modulation temperature was optimized to achieve the best separation and signal enhancement. The separation pattern of trimethylsilyl (TMS) derivatives of sterols was compared on two complementary column sets. Whilst the BPX5/BPX50 column set offers better overall separation, BPX50/BPX5 provides better peak shape and sensitivity. Comparison of the identification power of GCxGC-TOFMS against both the NIST05 MS library and a laboratory created (in-house) TOFMS library was carried out on a free sterols extract of urine, derivatised and spiked at the World Anti-Doping Agency (WADA) limit of 2 ng mL(-1). The average match quality for 19 analysed sterols on the BPX50/BPX5 column set was 950/1000 when searched against the in-house library; only four were identified against the NIST05 library, at a match threshold of 800. The match quality of GCxGC-TOFMS spectra was superior to that for analysis using 1D GC-TOFMS for sterols spiked in urine at 10 ng mL(-1). An r(2)>0.997 was obtained for the concentration range between 0.25 ng mL(-1) and 10 ng mL(-1) for three selected sterols. The lowest limit of detection (LOD) was obtained for estrone (0.1 ng mL(-1)) and the highest LOD was for 5alpha-androstan-3alpha,11beta-diol-17-one, epitestosterone and cholesteryl butyrate (1 ng mL(-1)), using a match threshold of at least 800 and signal-to-noise ratio of at least 10. TOFMS coupled to GCxGC enabled satisfactory identification of sterols in urine at their LOD. A minimum acceptable match (MAM) criterion for urinary sterols using 2D retention times and TOF mass spectra is introduced. This study shows that GCxGC-TOFMS yields high specificity for steroids derived from urine, with detection limits appropriate for use in doping control.
Similar articles
-
Comprehensive two-dimensional gas chromatography, retention indices and time-of-flight mass spectra of flavonoids and chalcones.J Chromatogr A. 2010 Dec 24;1217(52):8317-26. doi: 10.1016/j.chroma.2010.10.093. Epub 2010 Oct 30. J Chromatogr A. 2010. PMID: 21094947
-
Comprehensive two-dimensional gas chromatography improves separation and identification of anabolic agents in doping control.J Chromatogr A. 2010 Jan 1;1217(1):127-35. doi: 10.1016/j.chroma.2009.10.075. Epub 2009 Oct 30. J Chromatogr A. 2010. PMID: 19931865
-
Optimization of separation and detection conditions for the multiresidue analysis of pesticides in grapes by comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry.J Chromatogr A. 2008 May 9;1190(1-2):350-7. doi: 10.1016/j.chroma.2008.03.017. Epub 2008 Mar 12. J Chromatogr A. 2008. PMID: 18371973
-
Ion mobility spectrometry detection for gas chromatography.J Chromatogr A. 2008 Jan 4;1177(1):12-27. doi: 10.1016/j.chroma.2007.10.110. Epub 2007 Nov 12. J Chromatogr A. 2008. PMID: 18067900 Review.
-
Optimization aspects of comprehensive two-dimensional gas chromatography.J Chromatogr A. 2012 Sep 14;1255:38-55. doi: 10.1016/j.chroma.2012.02.064. Epub 2012 Mar 3. J Chromatogr A. 2012. PMID: 22425207 Review.
Cited by
-
A study of the precision and accuracy of peak quantification in comprehensive two-dimensional liquid chromatography in time.J Chromatogr A. 2010 Jun 25;1217(26):4313-27. doi: 10.1016/j.chroma.2010.04.039. Epub 2010 Apr 21. J Chromatogr A. 2010. PMID: 20462587 Free PMC article.
-
Highly sensitive and selective analysis of urinary steroids by comprehensive two-dimensional gas chromatography combined with positive chemical ionization quadrupole mass spectrometry.Analyst. 2012 Jul 7;137(13):3102-10. doi: 10.1039/c2an35087d. Epub 2012 May 18. Analyst. 2012. PMID: 22606686 Free PMC article.
-
Searching for Potential Markers of Glomerulopathy in Urine by HS-SPME-GC×GC TOFMS.Molecules. 2021 Mar 24;26(7):1817. doi: 10.3390/molecules26071817. Molecules. 2021. PMID: 33804943 Free PMC article. Clinical Trial.
-
Comprehensive 2-dimensional gas chromatography fast quadrupole mass spectrometry (GC × GC-qMS) for urinary steroid profiling: mass spectral characteristics with chemical ionization.Drug Test Anal. 2011 Nov-Dec;3(11-12):857-67. doi: 10.1002/dta.380. Epub 2011 Dec 6. Drug Test Anal. 2011. PMID: 22147458 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous