Symmetric nonrigid image registration: application to average brain templates construction
- PMID: 18982690
- DOI: 10.1007/978-3-540-85990-1_108
Symmetric nonrigid image registration: application to average brain templates construction
Abstract
Image registration aims at estimating a consistent mapping between two images. Common techniques consist in choosing arbitrarily one image as a reference image and the other one as a floating image, thus leading to the estimation of inconsistent mappings. We present a symmetric formulation of the registration problem that maps the two images in a common coordinate system halfway between them. This framework has been considered to devise an efficient strategy for mapping a large set of images in a common coordinate system. Some results are presented in the context of 3-D nonrigid brain MR image registration for the construction of average brain templates.
Similar articles
-
A fast nonrigid image registration with constraints on the Jacobian using large scale constrained optimization.IEEE Trans Med Imaging. 2008 Feb;27(2):271-81. doi: 10.1109/TMI.2007.905820. IEEE Trans Med Imaging. 2008. PMID: 18334448
-
A combined surface and volumetric registration (SAVOR) framework to study cortical biomarkers and volumetric imaging data.Med Image Comput Comput Assist Interv. 2009;12(Pt 1):713-20. doi: 10.1007/978-3-642-04268-3_88. Med Image Comput Comput Assist Interv. 2009. PMID: 20426051
-
A fast diffeomorphic image registration algorithm.Neuroimage. 2007 Oct 15;38(1):95-113. doi: 10.1016/j.neuroimage.2007.07.007. Epub 2007 Jul 18. Neuroimage. 2007. PMID: 17761438
-
Brain functional localization: a survey of image registration techniques.IEEE Trans Med Imaging. 2007 Apr;26(4):427-51. doi: 10.1109/TMI.2007.892508. IEEE Trans Med Imaging. 2007. PMID: 17427731 Review.
-
A review of 3D/2D registration methods for image-guided interventions.Med Image Anal. 2012 Apr;16(3):642-61. doi: 10.1016/j.media.2010.03.005. Epub 2010 Apr 13. Med Image Anal. 2012. PMID: 20452269 Review.
Cited by
-
Deformable medical image registration: a survey.IEEE Trans Med Imaging. 2013 Jul;32(7):1153-90. doi: 10.1109/TMI.2013.2265603. Epub 2013 May 31. IEEE Trans Med Imaging. 2013. PMID: 23739795 Free PMC article. Review.
-
SYMMETRIC NON-RIGID IMAGE REGISTRATION VIA AN ADAPTIVE QUASI-VOLUME-PRESERVING CONSTRAINT.Proc IEEE Int Symp Biomed Imaging. 2013 Apr;2013:230-233. doi: 10.1109/ISBI.2013.6556454. Proc IEEE Int Symp Biomed Imaging. 2013. PMID: 25750693 Free PMC article.
-
A momentum-based diffeomorphic demons framework for deformable MR-CT image registration.Phys Med Biol. 2018 Oct 24;63(21):215006. doi: 10.1088/1361-6560/aae66c. Phys Med Biol. 2018. PMID: 30353886 Free PMC article.
-
Mid-space-independent deformable image registration.Neuroimage. 2017 May 15;152:158-170. doi: 10.1016/j.neuroimage.2017.02.055. Epub 2017 Feb 24. Neuroimage. 2017. PMID: 28242316 Free PMC article.
-
Avoiding symmetry-breaking spatial non-uniformity in deformable image registration via a quasi-volume-preserving constraint.Neuroimage. 2015 Feb 1;106:238-51. doi: 10.1016/j.neuroimage.2014.10.059. Epub 2014 Oct 30. Neuroimage. 2015. PMID: 25449738 Free PMC article.
MeSH terms
LinkOut - more resources
Other Literature Sources
Medical