Determination of ranolazine in human plasma by LC-MS/MS and its application in bioequivalence study
- PMID: 18986788
- DOI: 10.1016/j.jpba.2008.09.033
Determination of ranolazine in human plasma by LC-MS/MS and its application in bioequivalence study
Abstract
A simple, sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for quantification of ranolazine in human plasma. The analytical method consists in the precipitation of plasma sample with methanol, followed by the determination of ranolazine by an LC-MS/MS. The analyte was separated on a Peerless Cyano column (33 mm x 4.6 mm, 3 microm) an isocratic mobile phase of methanol-water containing formic acid (1.0%, v/v) (65:35, v/v) at a flow rate of 1.0 ml/min. Protonated ions formed by a turbo ionspray in positive mode were used to detect analyte and internal standard (IS). The MS/MS detection was made by monitoring the fragmentation of m/z 428.20-->279.50 for ranolazine and m/z 448.30-->285.20 for internal standard on a triple quadrupole mass spectrometer. The method was validated over the concentration range of 5-2000 ng/ml for ranolazine in human plasma with correlation coefficient of 0.9937 (S.D.: +/-0.00367, range: 0.9895-0.9963). The accuracy and precision values obtained from six different sets of quality control samples analyzed in separate occasions ranged from 94.53 to 117.86 and 0.14% to 4.56%, respectively. Mean extraction recovery was 82.36-94.25% for three quality control (QC) samples and 88.37% for IS. Plasma samples were stable for three freeze-thaw cycles, or 24h ambient storage, or 1 and 3 months storage at -20 degrees C. Processed samples (ready for injection) were stable up to 72 h at autosampler (4 degrees C). The developed method was successfully applied for analyzing ranolazine in plasma samples for a bioequivalence study with 12 healthy volunteers.
Similar articles
-
Sensitive quantification of ranolazine in human plasma by liquid chromatography--tandem mass spectrometry with positive electrospray ionization.J Chromatogr B Analyt Technol Biomed Life Sci. 2007 Feb 1;846(1-2):346-50. doi: 10.1016/j.jchromb.2006.08.010. Epub 2006 Sep 7. J Chromatogr B Analyt Technol Biomed Life Sci. 2007. PMID: 16959552
-
Determination of gemifloxacin in different tissues of rat after oral dosing of gemifloxacin mesylate by LC-MS/MS and its application in drug tissue distribution study.J Pharm Biomed Anal. 2010 Jun 5;52(2):216-26. doi: 10.1016/j.jpba.2009.12.019. Epub 2009 Dec 29. J Pharm Biomed Anal. 2010. PMID: 20092976
-
Simultaneous determination of rosuvastatin and fenofibric acid in human plasma by LC-MS/MS with electrospray ionization: assay development, validation and application to a clinical study.J Pharm Biomed Anal. 2005 Sep 15;39(3-4):661-9. doi: 10.1016/j.jpba.2005.05.005. J Pharm Biomed Anal. 2005. PMID: 15970417
-
Measurement of oxidative stress parameters using liquid chromatography-tandem mass spectroscopy (LC-MS/MS).Toxicol Appl Pharmacol. 2008 Nov 15;233(1):100-6. doi: 10.1016/j.taap.2008.05.003. Epub 2008 May 9. Toxicol Appl Pharmacol. 2008. PMID: 18547599 Review.
-
Limits of suspicion, recognition and confirmation as concepts that account for the confirmation transitions at the detection limit for quantification by liquid chromatography-tandem mass spectrometry.J Chromatogr A. 2007 Oct 26;1169(1-2):103-10. doi: 10.1016/j.chroma.2007.08.065. Epub 2007 Sep 2. J Chromatogr A. 2007. PMID: 17880986 Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources