Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2008 Dec 15;48(5):1404-10.
doi: 10.1016/j.jpba.2008.09.033. Epub 2008 Sep 30.

Determination of ranolazine in human plasma by LC-MS/MS and its application in bioequivalence study

Affiliations

Determination of ranolazine in human plasma by LC-MS/MS and its application in bioequivalence study

Uttam Bhaumik et al. J Pharm Biomed Anal. .

Abstract

A simple, sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for quantification of ranolazine in human plasma. The analytical method consists in the precipitation of plasma sample with methanol, followed by the determination of ranolazine by an LC-MS/MS. The analyte was separated on a Peerless Cyano column (33 mm x 4.6 mm, 3 microm) an isocratic mobile phase of methanol-water containing formic acid (1.0%, v/v) (65:35, v/v) at a flow rate of 1.0 ml/min. Protonated ions formed by a turbo ionspray in positive mode were used to detect analyte and internal standard (IS). The MS/MS detection was made by monitoring the fragmentation of m/z 428.20-->279.50 for ranolazine and m/z 448.30-->285.20 for internal standard on a triple quadrupole mass spectrometer. The method was validated over the concentration range of 5-2000 ng/ml for ranolazine in human plasma with correlation coefficient of 0.9937 (S.D.: +/-0.00367, range: 0.9895-0.9963). The accuracy and precision values obtained from six different sets of quality control samples analyzed in separate occasions ranged from 94.53 to 117.86 and 0.14% to 4.56%, respectively. Mean extraction recovery was 82.36-94.25% for three quality control (QC) samples and 88.37% for IS. Plasma samples were stable for three freeze-thaw cycles, or 24h ambient storage, or 1 and 3 months storage at -20 degrees C. Processed samples (ready for injection) were stable up to 72 h at autosampler (4 degrees C). The developed method was successfully applied for analyzing ranolazine in plasma samples for a bioequivalence study with 12 healthy volunteers.

PubMed Disclaimer

Similar articles

Publication types

MeSH terms

LinkOut - more resources