Automated electrospray ionization FT-ICR mass spectrometry for petroleum analysis
- PMID: 18990588
- DOI: 10.1016/j.jasms.2008.10.001
Automated electrospray ionization FT-ICR mass spectrometry for petroleum analysis
Abstract
Analysis of petroleum samples at the molecular level by Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) typically requires a prolonged accumulation of ions and/or summing up a large number of scans. Here, a chip-based micro-ESI system (Advion NanoMate, Ithaca, NY) has been successfully automated in combination with FT-ICR MS analysis of petroleum samples. A foil-sealed 96-well glass plate prevents solvent evaporation, with no visible loss of sample after 20 h of continuous operation. Mass spectra obtained from the same sample but taken from different wells after various time delays were very similar. Data from replicate samples in different wells could be combined to enhance mass spectral signal-to-noise ratio and dynamic range. Furthermore, the automated data acquisition eliminates sample carryover, and produces heteroatom class distribution, double-bond equivalents (DBE), and carbon number very similar to those from the conventional (manual) micro-ESI experiments.
Similar articles
-
Developments in FT-ICR MS instrumentation, ionization techniques, and data interpretation methods for petroleomics.Mass Spectrom Rev. 2015 Mar-Apr;34(2):248-63. doi: 10.1002/mas.21438. Epub 2014 Jun 18. Mass Spectrom Rev. 2015. PMID: 24942384 Review.
-
Carbohydrate analysis by desorption electrospray ionization fourier transform ion cyclotron resonance mass spectrometry.Anal Chem. 2007 Nov 15;79(22):8812-5. doi: 10.1021/ac0713858. Epub 2007 Oct 6. Anal Chem. 2007. PMID: 17918969
-
Complementary Elucidation of the Molecular Characteristics of Groundwater Dissolved Organic Matter Using Ultrahigh-Resolution Mass Spectrometry Coupled with Negative- and Positive-Ion Electrospray Ionization.Environ Sci Technol. 2023 Mar 21;57(11):4690-4700. doi: 10.1021/acs.est.2c08816. Epub 2023 Mar 11. Environ Sci Technol. 2023. PMID: 36905367
-
Characterization of sulfide compounds in petroleum: selective oxidation followed by positive-ion electrospray Fourier transform ion cyclotron resonance mass spectrometry.Anal Chem. 2010 Aug 1;82(15):6601-6. doi: 10.1021/ac1010553. Anal Chem. 2010. PMID: 20586418
-
Screening of synthetic PDE-5 inhibitors and their analogues as adulterants: analytical techniques and challenges.J Pharm Biomed Anal. 2014 Jan;87:176-90. doi: 10.1016/j.jpba.2013.04.037. Epub 2013 May 6. J Pharm Biomed Anal. 2014. PMID: 23721687 Review.
Cited by
-
Analysis of lipids from crude lung tissue extracts by desorption electrospray ionization mass spectrometry and pattern recognition.Anal Biochem. 2011 Jan 15;408(2):289-96. doi: 10.1016/j.ab.2010.09.017. Epub 2010 Sep 22. Anal Biochem. 2011. PMID: 20868645 Free PMC article.
-
Leaving Group Effects in a Series of Electrosprayed CcHhN1 Anthracene Derivatives.J Am Soc Mass Spectrom. 2019 Nov;30(11):2306-2317. doi: 10.1007/s13361-019-02298-0. Epub 2019 Aug 10. J Am Soc Mass Spectrom. 2019. PMID: 31399941
-
Phase correction of Fourier transform ion cyclotron resonance mass spectra using MatLab.J Am Soc Mass Spectrom. 2011 Jan;22(1):138-47. doi: 10.1007/s13361-010-0006-7. Epub 2011 Jan 28. J Am Soc Mass Spectrom. 2011. PMID: 21472552
-
Optimization and Application of APCI Hydrogen-Deuterium Exchange Mass Spectrometry (HDX MS) for the Speciation of Nitrogen Compounds.J Am Soc Mass Spectrom. 2015 Sep;26(9):1522-31. doi: 10.1007/s13361-015-1166-2. Epub 2015 Jun 27. J Am Soc Mass Spectrom. 2015. PMID: 26115964
-
Surface-Induced Dissociation: An Effective Method for Characterization of Protein Quaternary Structure.Anal Chem. 2019 Jan 2;91(1):190-209. doi: 10.1021/acs.analchem.8b05071. Epub 2018 Dec 18. Anal Chem. 2019. PMID: 30412666 Free PMC article. Review.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources