Preoperative 123I/99mTc-sestamibi subtraction SPECT and SPECT/CT in primary hyperparathyroidism
- PMID: 18997051
- DOI: 10.2967/jnumed.108.054858
Preoperative 123I/99mTc-sestamibi subtraction SPECT and SPECT/CT in primary hyperparathyroidism
Abstract
The trend toward focused surgical parathyroidectomy requires precise preoperative localization of parathyroid lesions in patients with hyperparathyroidism. The purpose of this study was to directly compare the diagnostic accuracy of (99m)Tc-sestamibi/(123)I subtraction SPECT with SPECT/CT for the localization of abnormal parathyroid glands in patients with primary hyperparathyroidism.
Methods: A total of 61 consecutive surgical patients with primary hyperparathyroidism underwent both (123)I/(99m)Tc-sestamibi subtraction SPECT and SPECT/CT scans preoperatively, using a hybrid SPECT/CT instrument that combined a dual-detector SPECT camera with a 6-slice multidetector spiral CT scanner. Four hours after being given (123)I-sodium iodide orally, each patient received (99m)Tc-sestamibi intravenously, followed immediately by a simultaneous, dual-isotope SPECT scan of the neck and upper chest. Then, without moving the patient, we performed a non-contrast-enhanced CT scan of the same body region. Normalization and subtraction of the (123)I SPECT images from the (99m)Tc SPECT images were performed. The subtraction SPECT and the coregistered fused SPECT/CT studies were interpreted separately, with images scored on a 5-point scale. Surgical and histopathologic findings were used as the standard of comparison.
Results: Surgery was successful in 57 patients (solitary parathyroid adenoma in 48 patients, double parathyroid adenomas in 6 patients, and 10 hyperplastic parathyroid glands in 3 patients). The sensitivities of SPECT (50/70 = 71%) and SPECT/CT (49/70 = 70%) were similar (P = 0.779). The specificity of SPECT/CT (26/27 = 96%) was significantly greater than that of SPECT (13/27 = 48%; P = 0.006). The receiver-operating-characteristic area under the curve of SPECT/CT (0.833) was significantly greater than that of SPECT (0.632; P < 0.001).
Conclusion: SPECT/CT is significantly more specific than dual-isotope subtraction SPECT for the preoperative identification of parathyroid lesions in patients with primary hyperparathyroidism.
Similar articles
-
Accuracy of preoperative localization studies and intraoperative parathyroid hormone assay in patients with primary hyperparathyroidism and double adenoma.J Am Coll Surg. 2003 Nov;197(5):739-46. doi: 10.1016/S1072-7515(03)00676-8. J Am Coll Surg. 2003. PMID: 14585407
-
'Low dose' 99mTc-Sestamibi for radioguided surgery of primary hyperparathyroidism.Eur J Surg Oncol. 2005 Mar;31(2):191-6. doi: 10.1016/j.ejso.2004.10.008. Eur J Surg Oncol. 2005. PMID: 15698737
-
Comparison of double-phase 99mTc-sestamibi with 123I-99mTc-sestamibi subtraction SPECT in hyperparathyroidism.AJR Am J Roentgenol. 1997 Dec;169(6):1671-4. doi: 10.2214/ajr.169.6.9393188. AJR Am J Roentgenol. 1997. PMID: 9393188
-
Parathyroid scintigraphy in patients with primary hyperparathyroidism: 99mTc sestamibi SPECT and SPECT/CT.Radiographics. 2008 Sep-Oct;28(5):1461-76. doi: 10.1148/rg.285075055. Radiographics. 2008. PMID: 18794320 Review.
-
Sestamibi parathyroid imaging.Semin Nucl Med. 1995 Jul;25(3):221-34. doi: 10.1016/s0001-2998(95)80012-3. Semin Nucl Med. 1995. PMID: 7570042 Review.
Cited by
-
Comparison of five parathyroid scintigraphic protocols.Int J Mol Imaging. 2013;2013:921260. doi: 10.1155/2013/921260. Epub 2013 Jan 21. Int J Mol Imaging. 2013. PMID: 23431436 Free PMC article.
-
2009 EANM parathyroid guidelines.Eur J Nucl Med Mol Imaging. 2009 Jul;36(7):1201-16. doi: 10.1007/s00259-009-1131-z. Eur J Nucl Med Mol Imaging. 2009. PMID: 19471928
-
Near-Infrared Autofluorescence for Parathyroid Detection During Endocrine Neck Surgery: A Randomized Clinical Trial.JAMA Surg. 2025 Jul 16:e252233. doi: 10.1001/jamasurg.2025.2233. Online ahead of print. JAMA Surg. 2025. PMID: 40668552 Free PMC article.
-
Endocrine radionuclide scintigraphy with fusion single photon emission computed tomography/computed tomography.World J Radiol. 2016 Jun 28;8(6):635-55. doi: 10.4329/wjr.v8.i6.635. World J Radiol. 2016. PMID: 27358692 Free PMC article.
-
Incremental Value of Sestamibi SPECT/CT Over Dual-Phase Planar Scintigraphy in Patients With Primary Hyperparathyroidism and Inconclusive Ultrasound.Front Med (Lausanne). 2019 Jul 16;6:164. doi: 10.3389/fmed.2019.00164. eCollection 2019. Front Med (Lausanne). 2019. PMID: 31380379 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical