Corneal elevation and thickness in relation to the refractive status measured with the Pentacam Scheimpflug system
- PMID: 19006736
- DOI: 10.1016/j.jcrs.2008.07.018
Corneal elevation and thickness in relation to the refractive status measured with the Pentacam Scheimpflug system
Abstract
Purpose: To prospectively evaluate the elevation and thickness data in patients with different types of refractive errors.
Setting: Department of Ophthalmology, Ankara University Faculty of Medicine, Ankara, Turkey.
Methods: After the refractive errors in 215 consecutive patients were determined, corneal topography measurements with the Pentacam Scheimpflug system were taken in the right eye of all patients and the right eye of 31 healthy emmetropic volunteers. The eyes with refractive errors were assigned to 1 of the following 4 groups: myopia, myopic astigmatism, high myopia, and hyperopia. The means of the parameters of 3 Pentacam measurements were evaluated and compared.
Results: Eyes with high myopia had significantly lower mean corneal thickness and volume measurements and higher mean anterior chamber depth (ACD) and anterior chamber volume (ACV) measurements than eyes in the other groups. The mean ACD, ACV, and anterior chamber angle were significantly lower in hyperopic eyes than in the other groups. The mean keratometry readings were statistically significantly flatter in the hyperopia group than in the other 4 groups.
Conclusions: Eyes with high myopia had thinner corneas and deeper anterior chambers than emmetropic eyes and eyes in the other ametropic groups. Excluding eyes with hyperopia, which had significantly flat anterior and posterior elevation measurements, the elevation measurements in eyes with myopic refractive errors did not differ from each other or from those in emmetropic eyes. These findings may help clinicians and refractive surgeons using the Pentacam to better define normal from abnormal in the clinical setting.
Similar articles
-
Corneal changes after laser refractive surgery for myopia: comparison of Orbscan II and Pentacam findings.J Cataract Refract Surg. 2007 May;33(5):841-7. doi: 10.1016/j.jcrs.2007.01.019. J Cataract Refract Surg. 2007. PMID: 17466859
-
Reliability of Orbscan II topography measurements in relation to refractive status.J Cataract Refract Surg. 2005 Aug;31(8):1607-13. doi: 10.1016/j.jcrs.2005.01.013. J Cataract Refract Surg. 2005. PMID: 16129300
-
Anterior chamber measurements using Pentacam rotating Scheimpflug camera.J Cataract Refract Surg. 2006 Mar;32(3):456-9. doi: 10.1016/j.jcrs.2005.12.103. J Cataract Refract Surg. 2006. PMID: 16631057 Clinical Trial.
-
[Pentacam--the new way for anterior eye segment imaging and mapping].Klin Oczna. 2005;107(10-12):728-31. Klin Oczna. 2005. PMID: 16619832 Review. Polish.
-
Measuring the cornea: the latest developments in corneal topography.Curr Opin Ophthalmol. 2007 Jul;18(4):325-33. doi: 10.1097/ICU.0b013e3281ca7121. Curr Opin Ophthalmol. 2007. PMID: 17568210 Review.
Cited by
-
Corneal thickness, epithelial thickness and axial length differences in normal and high myopia.BMC Ophthalmol. 2015 May 7;15:49. doi: 10.1186/s12886-015-0039-6. BMC Ophthalmol. 2015. PMID: 25947156 Free PMC article.
-
Anterior chamber depth in normal subjects by rotating scheimpflug imaging.Saudi J Ophthalmol. 2011 Jul;25(3):255-9. doi: 10.1016/j.sjopt.2011.04.005. Epub 2011 Apr 30. Saudi J Ophthalmol. 2011. PMID: 23960933 Free PMC article.
-
Corneal elevation indices and pachymetry values of Saudi myopes using scheimpflug imaging.Saudi Med J. 2020 Feb;41(2):168-176. doi: 10.15537/smj.2020.2.24876. Saudi Med J. 2020. PMID: 32020151 Free PMC article.
-
Comparison of central corneal thickness using non-contact tono-pachymeter (Tonopachy) with ultrasound pachymetry in normal children and in children with refractive error.Indian J Ophthalmol. 2021 Aug;69(8):2053-2059. doi: 10.4103/ijo.IJO_364_21. Indian J Ophthalmol. 2021. PMID: 34304177 Free PMC article.
-
Scheimpflug analysis of corneal power changes after hyperopic small incision lenticule extraction.BMC Ophthalmol. 2021 Jul 20;21(1):282. doi: 10.1186/s12886-021-02043-w. BMC Ophthalmol. 2021. PMID: 34284749 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources