Effect of intraocular lens design on posterior capsule opacification
- PMID: 19006748
- DOI: 10.1016/j.jcrs.2008.07.029
Effect of intraocular lens design on posterior capsule opacification
Abstract
Posterior capsule opacification (PCO) remains the most common long-term complication after cataract surgery. Many studies have attempted to identify factors that influence the development of PCO. The aim of this systematic review based on Cochrane methodology was to summarize the effects of intraocular lens (IOL) geometry, including modifications of the IOL optic (especially optic edge design) and haptics, on the development of PCO. Twenty-six prospective randomized controlled trials with a follow-up of at least 12 months were included. In 5 of 7 studies, visual acuity was better in sharp-edged IOLs than in round-edged IOL. The PCO score was significantly lower with sharp-edged IOLs but did not differ significantly between 1-piece and 3-piece open-loop IOLs. Because of the significant difference in the PCO score, sharp-edged IOL optics should be preferred to round-edged IOL optics.
Similar articles
-
Intraocular lens optic edge design for the prevention of posterior capsule opacification after cataract surgery.Cochrane Database Syst Rev. 2021 Aug 16;8(8):CD012516. doi: 10.1002/14651858.CD012516.pub2. Cochrane Database Syst Rev. 2021. PMID: 34398965 Free PMC article.
-
Interventions for preventing posterior capsule opacification.Cochrane Database Syst Rev. 2007 Jul 18;(3):CD003738. doi: 10.1002/14651858.CD003738.pub2. Cochrane Database Syst Rev. 2007. Update in: Cochrane Database Syst Rev. 2010 Feb 17;(2):CD003738. doi: 10.1002/14651858.CD003738.pub3. PMID: 17636731 Updated.
-
Interventions for preventing posterior capsule opacification.Cochrane Database Syst Rev. 2010 Feb 17;2010(2):CD003738. doi: 10.1002/14651858.CD003738.pub3. Cochrane Database Syst Rev. 2010. PMID: 20166069 Free PMC article.
-
Long-term effect of sharp optic edges of a polymethyl methacrylate intraocular lens on posterior capsule opacification: a randomized trial.Ophthalmology. 2005 Nov;112(11):2004-8. doi: 10.1016/j.ophtha.2005.06.021. Epub 2005 Sep 15. Ophthalmology. 2005. PMID: 16168485 Clinical Trial.
-
Effect of intraocular lens optic edge design and material on fibrotic capsule opacification and capsulorhexis contraction.J Cataract Refract Surg. 2004 Sep;30(9):1875-82. doi: 10.1016/j.jcrs.2004.01.042. J Cataract Refract Surg. 2004. PMID: 15342049 Clinical Trial.
Cited by
-
Inhibition of pirfenidone on TGF-beta2 induced proliferation, migration and epithlial-mesenchymal transition of human lens epithelial cells line SRA01/04.PLoS One. 2013;8(2):e56837. doi: 10.1371/journal.pone.0056837. Epub 2013 Feb 21. PLoS One. 2013. PMID: 23437252 Free PMC article.
-
Protective Effects of One 2,4-Dihydro-3H-Pyrazol-3-one Derivative against Posterior Capsular Opacification by Regulation of TGF-β2/SMADs and Non-SMAD Signaling, Collagen I, and Fibronectin Proteins.Curr Issues Mol Biol. 2022 Oct 19;44(10):5048-5066. doi: 10.3390/cimb44100343. Curr Issues Mol Biol. 2022. PMID: 36286058 Free PMC article.
-
The Protective Effect of Metformin Use on Early Nd:YAG Laser Capsulotomy.Invest Ophthalmol Vis Sci. 2021 Aug 2;62(10):24. doi: 10.1167/iovs.62.10.24. Invest Ophthalmol Vis Sci. 2021. PMID: 34415985 Free PMC article.
-
Comparison of Clinical Outcomes, Visual Quality and Visual Function of Two Presbyopia-Correcting Intraocular Lenses Made from the Same Material, but with Different Design and Optics.J Clin Med. 2021 Jul 24;10(15):3268. doi: 10.3390/jcm10153268. J Clin Med. 2021. PMID: 34362052 Free PMC article.
-
Bottom-up fabrication of zwitterionic polymer brushes on intraocular lens for improved biocompatibility.Int J Nanomedicine. 2016 Dec 20;12:127-135. doi: 10.2147/IJN.S107491. eCollection 2017. Int J Nanomedicine. 2016. PMID: 28053528 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical