Quantitative determination of pharmaceutical drug formulations by near-infrared spectroscopic imaging
- PMID: 19007460
- DOI: 10.1366/000370208786401590
Quantitative determination of pharmaceutical drug formulations by near-infrared spectroscopic imaging
Abstract
Over the last decade Fourier transform infrared (FT-IR) and near-infrared (NIR) spectroscopic imaging with focal plane array (FPA) detectors have proved powerful techniques for the rapid visualization of samples by a combination of spectroscopic and spatial information. Using these methods, selected sample areas can be analyzed with reference to the identification and localization of chemical species by FT-IR spectroscopy in the transmission or attenuated total reflection (ATR) mode and by NIR spectroscopy in diffuse reflection with a lateral resolution in the micrometer range. The present communication focuses on the quantitative determination of the active ingredient composition of a solid drug formulation by NIR spectroscopic imaging with a focal plane array detector and the results obtained are compared to the quantitative data obtained by conservative light-fiber NIR spectroscopic diffuse reflection measurements with a single-element detector. The communication also addresses the issue of penetration depth of NIR radiation into the investigated solid material.
Similar articles
-
Rapid determination of vitamin C by NIR, MIR and FT-Raman techniques.J Pharm Pharmacol. 2002 Sep;54(9):1247-55. doi: 10.1211/002235702320402099. J Pharm Pharmacol. 2002. PMID: 12356279 Review.
-
Transfer of NIR calibrations for pharmaceutical formulations between different instruments.J Pharm Biomed Anal. 2006 Apr 11;41(1):89-98. doi: 10.1016/j.jpba.2005.10.042. Epub 2006 Jan 6. J Pharm Biomed Anal. 2006. PMID: 16406454
-
Pharmaceutical applications of vibrational chemical imaging and chemometrics: a review.J Pharm Biomed Anal. 2008 Nov 4;48(3):533-53. doi: 10.1016/j.jpba.2008.08.014. Epub 2008 Aug 22. J Pharm Biomed Anal. 2008. PMID: 18819769 Review.
-
Near-infrared chemical imaging (NIR-CI) on pharmaceutical solid dosage forms-comparing common calibration approaches.J Pharm Biomed Anal. 2008 Nov 4;48(3):554-61. doi: 10.1016/j.jpba.2008.07.019. Epub 2008 Jul 31. J Pharm Biomed Anal. 2008. PMID: 18774667
-
Detection of trace materials with Fourier transform infrared spectroscopy using a multi-channel detector.Analyst. 2006 Jan;131(1):126-31. doi: 10.1039/b511243e. Epub 2005 Nov 25. Analyst. 2006. PMID: 16365673
Cited by
-
Rapid Determination of Nutritional Parameters of Pasta/Sauce Blends by Handheld Near-Infrared Spectroscopy.Molecules. 2019 May 28;24(11):2029. doi: 10.3390/molecules24112029. Molecules. 2019. PMID: 31141878 Free PMC article.
-
Identification of four Sedum plant medicines by fourier transform infrared spectra.Pharmacogn Mag. 2012 Apr;8(30):107-10. doi: 10.4103/0973-1296.96551. Pharmacogn Mag. 2012. PMID: 22701282 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous