Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2009 Feb;18(1):35-40.
doi: 10.1016/j.breast.2008.09.005. Epub 2008 Nov 17.

Mammographic density estimation: comparison among BI-RADS categories, a semi-automated software and a fully automated one

Affiliations
Free article
Comparative Study

Mammographic density estimation: comparison among BI-RADS categories, a semi-automated software and a fully automated one

Alberto Tagliafico et al. Breast. 2009 Feb.
Free article

Abstract

Although breast density is considered a strong predictor of breast cancer risk, its quantitative assessment is difficult. The aim of this study is to demonstrate that breast density assessment with a fully automated software is feasible and correlates with the semi-automated evaluation and the quantitative BI-RADS standards. A data set of 160 mammograms was evaluated by three blinded radiologists. Intra-observer (reader 1: k=0.71; reader 2: k=0.76; reader 3: k=0.62) and inter-observer (reader 1 vs reader 2: k=0.72; reader 2 vs reader 3: k=0.80; reader 3 vs reader 1: k=0.72) variability for the semi-automated software were good on a four-grade scale (D1/D2/D3/D4) and correlated with BI-RADS evaluation made by other two blinded radiologists (r=0.65, p<0.01). Inter-observer (reader 1 vs reader 2: k=0.85; reader 2 vs reader 3: k=0.91; reader 3 vs reader 1: k=0.85) variability for the semi-automated software was very good on a two-grade scale (D1-D2/D3-D4). The use of the fully automated software eliminated intra- and inter-observer differences, correlated with BI-RADS categories (r=0.62, p<0.01) and can replace the semi-automated one (Bland-Altman statistics). Our study demonstrates that automated estimation of breast density is feasible and eliminates subjectivity. Furthermore both the semi-automated and the fully automated density estimation are more accurate than BI-RADS quantitative evaluation and could also be used in the daily clinical practice.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources